2nd edition, 31-03-2020
7000.05061, 2nd edition, 31-03-2020
7000.05061
Installation
16
Fig. 6:
Comparison of round flange and quadratic flange
4.2
Electrical connection
4.2.1
Notes on the electrical connection
NOTICE!
Electrostatic discharges to the motor connections can damage the electronic components
Observe the ESD protective measures.
Carry out work only at ESD-protected workstations.
Connect the connections as per the pin assignment (see chap. 4.2.2.3, p. 19)
NOTICE!
Extreme static or dynamic loads on the ribbon cable can cause the cable to be damaged.
Make sure that the ribbon cable is not subjected to abrasion, crushing or excessively
tight bending radii during installation and operation.
With frequent bending, the bending radius must not be less than 10 mm. The possible
number of bending cycles increases as the bending radius increases.
Do not bend the cable at temperatures < –10 °C.
Comply with permissible loads (see Tab. 3).
R1,5
2610…B SC
3242…BX4 SC
26
22
6x
60°