Tab. 3:
Permissible loads of the ribbon cables
Motor series
Contact spacing
Permissible loads
22xx…BX4(S) SC
1.27 AWG28
Tensile load: <30 N
Continuous tensile load: <17 N
Bending radius with one-off installation: >1.2 mm
32xx…BX4 SC / SCDC
2.54 AWG24
Tensile load: <60 N
Continuous tensile load: <20 N
Bending radius with one-off installation: >1.8 mm
26xx…B SC
1.00 AWG28
Tensile load: < 20 N
Continuous tensile load: < 11 N
Bending radius with one-off installation: >1.2 mm
1525…BRC / 1935…BRC
1.00 AWG28
Tensile load: < 20 N
Continuous tensile load: < 11 N
Bending radius with one-off installation: >1.2 mm
3153…BRC
1.27 AWG26
Tensile load: < 20 N
Continuous tensile load: < 17 N
Bending radius with one-off installation: >1.2 mm
2214…BXT H SC
1.27 AWG28
Tensile load: <30 N
Continuous tensile load: <17 N
Bending radius with one-off installation: >1.2 mm
3216…BXT H SC
2.54 AWG24
Tensile load: <60 N
Continuous tensile load: <20 N
Bending radius with one-off installation: >1.8 mm
4221…BXT H SC
2.54 AWG24
Tensile load: <60 N
Continuous tensile load: <20 N
Bending radius with one-off installation: >1.8 mm