36
Operation
5
Commissioning
5.1
Before starting up the servomotor together with a mechanism, the following points must be che-
cked:
The motor has been installed according to the specifications.
The ribbon cable of the motor is connected according to the requirements (risk of polarity
reversal!) and is laid so that it cannot be damaged during operation. The maximum load values
must be noted and observed. (See
section 7 "Technical Data"
).
Lengthening the connection leads can affect the function and properties with respect to EMC. All
connection leads may not exceed a length of 3 m.
The connected mechanism is installed free of blockages.
The loads and stresses on the shaft (axial, radial and torques) are within the specified values (see
section 7 "Technical Data"
).
CAUTION!
Risk of injuries
A risk of injuries can result from protruding rotating or moving parts of the driven mechanism.
Cover rotating and moving parts with appropriate devices.
f
CAUTION!
Risk of burns
Depending on the load and ambient temperature, very high temperatures can occur on the surface
of the unit.
Contact protection (guards) must be provided if necessary.
f