71
5 Parameter description
5.7 Configuration at delivery
The standard configuration n parameters with which the units are delivered are listed below. These
settings can also be reloaded at any time with the command FCONFIG, followed by a hardware
reset.
3564K024B CS:
FAULHABER command
Description
CONTMOD
Normal operation
APL0
Position limits deactivated
SOR0
Velocity presetting via RS232
MOTTYP8
Motor type 3564K024B K1155
ERROUT
Fault pin = error output
HP7
All inputs react to rising edge
HB0, HD0
No Hard Blocking limit switches defined
HOSP100
Homing Speed = 100 rpm
SHA0, SHL0, SHN0
No FAULHABER homing defined
ADR
Analog direction of rotation right
LPC8000
Peak current limitation = 8 A
LCC2800
Continuous current limitation = 2.8 A
AC30000
Acceleration = 30 000 r/s²
DEC30000
Deceleration ramp = 30 000 r/s²
SR1
Sampling rate = 100 μs
I40
I-term of velocity controller
POR8
P-term of velocity controller
PP12
P-term of position controller
PD6
D-term of position controller
CI50
I-term of current controller
SP12000
Limitation of maximum speed to 12 000 rpm
MV0
Smallest analog speed
MAV25
Smallest analog voltage
LL1800000000
Upper positioning range limit
LL-1800000000
Lower positioning range limit
LPN16
Numerical value for pulse output
STW1
Step width for special mode
STN1000
Number of steps for special mode
ENCRES2048
Resolution of external encoder
DEV30000
Do not monitor deviation error
DCE200
Error delay 2 sec.
CORRIDOR20
Target corridor for positioning
SIN1
Do not allow block commutation
SETPLC
Digital inputs PLC-compatible
NET0
Multiplex mode is deactivated
BAUD9600
Transfer rate 9 600 baud
NODEADR0
Node number = 0
COMPATIBLE0
Not in compatibility mode
ANSW2
Asynchronous responses activated
POHOSEQ0
No homing sequence after switching on
DIPROG
Sequence programs deactivated
DI
Power output stage deactivated
V0
Target speed value = 0 rpm