55
Jiefang J6 China IV, China V series instruction
Co
rr
ec
t
d
riv
in
g
Correct operation
Correct driving
Normal engine start-up
Operation before start-up
- Verify that the manual valve is in the parking
position.
- Verify that the speed control lever is in the
NEUTRAL position.
- Turn the key to the ON position and observe
whether the instrument is normal.
- Step down the clutch pedal, continue to turn the
key to the S block, turn on the start switch, start the
engine. Once the engine starts, release the key
immediately and make it return to the ON gear
automatically.
- After the engine is running smoothly, release the
clutch pedal at a constant speed.
- After starting, pay attention to observe the oil
pressure, coolant temperature, charging indication,
etc.
Caution
⊙
Do not step on the accelerator violently after
starting so as to prevent the oil pressure from
sudden rising and the oil too thick. Therefore, the
friction surface of each part can not be reached by
the oil in time, thus accelerating the wear of parts.
⊙
The continuous working time of the starter shall
not exceed 30 s, and the two-times starting interval
shall be at least 1 minute. If the starter fails to start
three times continuously, the oil circuit and circuit
should be checked. The life of the starter and
battery will be damaged if the starter fails to start
three times continuously.
⊙
In order to improve the service life of the
booster, the engine should run for (3 ~ 5) minutes at
idle speed before parking, so that it is fully
lubricated.
Engine cold start warm-up
When the external temperature is lower than 0
℃
,
the preheating indicator
lights up, indicating
that the engine is preheating. Do not start the engine
until the preheating indicator lights out. After the
engine is started, run the engine at low speed for
several minutes, and preheat the engine.
When the water temperature reaches more than
50
℃
, start the engine. During the preheating
process, observe the operation of each instrument,
indicator lamp and warning lamp. Be careful not to
run at idle for a long time.
During the initial preheating, each indicator lamp
is on, but the alarm lamp
goes out with the increase of oil and gas pressure
after the vehicle is started.
When the pointer reaches 0.55MPa, the oil
pressure reaches 0.1MPa, and the coolant
temperature reaches more than 50
℃
, the vehicle is
in the starting condition.
At this time, the parking brake lamp
is still
on, reminding you to release the parking brake
valve before starting it.
Summary of Contents for J6 Jiefang IV Series
Page 1: ...1 Jiefang Truck Operation Manual J6 China IV China V series FAW Co Ltd ...
Page 7: ......
Page 8: ......
Page 9: ...1 J6 China IV Series ...
Page 115: ...107 Jiefang J6 China IV China V series instruction On board tools Appendix and Data ...
Page 121: ...J6 pilotage tractor ...
Page 216: ...208 Jiefang J6 China IV China V series instruction Appendix and Data ...