Valve clearance:
Intake valve (IN)
0.08 mm (0.003 in)
Exhaust valve (EX)
0.10 mm (0.004 in)
1.
Check the valve clearance with a feeler gauge between
rocker arm (2) and valve shaft (1) on both valves, adjust if
necessary.
1.
Hold the hexagon nut (1) on the rocker arm and loosen
counter nut (2).
2.
Adjust the hexagon nut, until the feeler gauge can be
inserted and pulled out with little resistance after retightening
the counter nut.
1.
Install the valve cover (2) with a new seal (3).
2.
Tighten the fastening screws (1) evenly.
3.
After a short test run, check the engine for leaks.
Checking the valve clearance
Fig. 85
Adjusting the valve clearance
Fig. 86
Final work
Fig. 87
Maintenance – Annually
DRP15X
83
Summary of Contents for DYNAPAC DRP15X
Page 6: ...Table of contents DRP15X 6 ...
Page 7: ...1 Introduction Introduction DRP15X 7 ...
Page 11: ...2 Technical data Technical data DRP15X 11 ...
Page 15: ...3 Concerning your safety Concerning your safety DRP15X 15 ...
Page 39: ...4 Indicators and control elements Indicators and control elements DRP15X 39 ...
Page 45: ...5 Checks prior to start up Checks prior to start up DRP15X 45 ...
Page 53: ...6 Operation Operation DRP15X 53 ...
Page 62: ...Operation Parking the machine in secured condition DRP15X 62 ...
Page 63: ...7 Loading transporting the machine Loading transporting the machine DRP15X 63 ...
Page 68: ...Loading transporting the machine Transport wheels DRP15X 68 ...
Page 69: ...8 Maintenance Maintenance DRP15X 69 ...
Page 109: ...9 Troubleshooting Troubleshooting DRP15X 109 ...
Page 116: ...Troubleshooting What to do if the engine has flooded DRP15X 116 ...
Page 117: ...10 Disposal Disposal DRP15X 117 ...
Page 119: ......
Page 120: ......