9.8 DCI faults
Fault
Possible cause
Remedy
LED (a) flashes
Switching on: The LED (a) flashes for
approx 1
-
2 seconds after the vibration
has been switched on.
Vibration frequency too low
LED (a) lights up
No vibration detected
Start the engine, set the throttle lever to
position “MAX” (switch vibration on).
Check the connection of the acceleration
sensor.
Acceleration sensor is not connected.
Check the connection of the acceleration
sensor.
Cable breakage
Inform our Customer Service Department
The displayed
measuring values
are not plausible.
The acceleration sensor is not fastened
correctly.
Shut down the engine and check the fas-
tening screws of the acceleration sensor.
Weak spots in the road substructure
In unfavourable cases, an excessively
varying material composition or moisture
in the road substructure can influence the
measuring results.
On material which is too dry or moist,
lower measuring values will be displayed.
1
2
3
4
5 6 7
8
9
10
a
B-DIS-1054
Fig. 136
Troubleshooting – DCI faults
DRP45DX
113
Summary of Contents for DYNAPAX DRP45DX
Page 6: ...Table of contents DRP45DX 6...
Page 7: ...1 Introduction Introduction DRP45DX 7...
Page 11: ...2 Technical data Technical data DRP45DX 11...
Page 15: ...3 Concerning your safety Concerning your safety DRP45DX 15...
Page 41: ...4 Indicators and control elements Indicators and control elements DRP45DX 41...
Page 47: ...5 Checks prior to start up Checks prior to start up DRP45DX 47...
Page 53: ...6 Operation Operation DRP45DX 53...
Page 61: ...7 Loading transporting the machine Loading transporting the machine DRP45DX 61...
Page 64: ...Loading transporting the machine Lashing the machine to the transport vehicle DRP45DX 64...
Page 65: ...8 Maintenance Maintenance DRP45DX 65...
Page 102: ...Maintenance As required DRP45DX 102...
Page 103: ...9 Troubleshooting Troubleshooting DRP45DX 103...
Page 114: ...Troubleshooting DCI faults DRP45DX 114...
Page 115: ...10 Disposal Disposal DRP45DX 115...
Page 117: ......
Page 118: ......