9.3 Starting the engine with jump leads
NOTICE!
A wrong connection will cause severe damage
in the electric system.
–
Bridge the machine only with a 12 Volt auxiliary
battery.
1.
Open the protection hood and secure it to prevent unin-
tended closing.
2.
Remove the bracket of the battery.
3.
First connect the plus pole of the external battery to the plus
pole of the starter battery using the first jump lead.
4.
Next, connect the second jump lead to the minus pole of the
energizing external battery and then to the minus pole of the
starter battery.
5.
Start the engine
6.
After starting disconnect the minus poles first and the plus
poles after.
7.
Install the bracket of the battery.
8.
Close the protection hood.
Fig. 117
Troubleshooting – Starting the engine with jump leads
BPR 50/55 D