8.11.4
Checking the oil level in the exciter housing
NOTICE!
Components may get damaged!
–
Use only oil of the permitted specification
Chapter 8.4 „List of fuels and lubri-
.
–
Do not use low-ash engine oils for the exciter
shaft housing.
Protective equipment:
n
Working clothes
n
Safety shoes
n
Protective gloves
1.
Park the machine on level ground.
2.
Park the machine safely
Chapter 6.4 „Parking the machine
in secured condition“ on page 55
.
3.
Allow the machine to cool down.
4.
Clean the area around the bleeding screw (1) and filling/drain
plug (2).
5.
Unscrew the bleeding screw.
6.
Unscrew the filling/drain plug and check the oil level; top up if
necessary.
ð
Nominal value:
Bottom edge of filling/drain bore.
7.
Clean the bleed screw and filling/drain plug and screw them
in with a low-strength sealing agent (e.g. spare parts number:
DL 009 700 16).
8.11.5
Measures prior to extended shut-down period
8.11.5.1
Measures before shutting down
If the machine is shut down for a longer period of time, e.g. winter
season, the following work must be carried out:
1.
Clean the machine thoroughly.
2.
Clean the water separator.
3.
Fill the fuel tank with diesel fuel, to prevent the formation of
condensation water in the tank.
4.
Change engine oil and oil filter if the oil change had been car-
ried out more than 300 operating hours ago.
5.
Change the fuel filter.
6.
After shutting down store the machine under cover in a dry
and well ventilated room.
7.
Protect the cooled down engine against dust and moisture.
2
1
B-692-0015
Fig. 111
Maintenance – As required
DRP45DX
94
Summary of Contents for DYNAPAC DRP45DX
Page 2: ...2 ...
Page 6: ...Table of contents DRP45DX 6 ...
Page 7: ...1 Introduction Introduction DRP45DX 7 ...
Page 11: ...2 Technical data Technical data DRP45DX 11 ...
Page 15: ...3 Concerning your safety Concerning your safety DRP45DX 15 ...
Page 40: ...Concerning your safety Signage DRP45DX 40 ...
Page 41: ...4 Indicators and control elements Indicators and control elements DRP45DX 41 ...
Page 43: ...5 Checks prior to start up Checks prior to start up DRP45DX 43 ...
Page 49: ...6 Operation Operation DRP45DX 49 ...
Page 56: ...Operation Parking the machine in secured condition DRP45DX 56 ...
Page 57: ...7 Loading transporting the machine Loading transporting the machine DRP45DX 57 ...
Page 61: ...8 Maintenance Maintenance DRP45DX 61 ...
Page 96: ...6 Check the oil levels 7 Clean the machine thoroughly Maintenance As required DRP45DX 96 ...
Page 97: ...9 Troubleshooting Troubleshooting DRP45DX 97 ...
Page 106: ...Troubleshooting Malfunctions during operation DRP45DX 106 ...
Page 107: ...10 Disposal Disposal DRP45DX 107 ...
Page 109: ......
Page 110: ......