The following Click parameters can viewed, accessed, and changed as required:
Parameter
Value
Description
Speed
20-260
Tempo of the metronome in Beats
Per Minute (BPM)
Sound
6
Type of sound
Beats
1-9
Number of notes per beat
Rhythm
0-127
Metronome volume
Volume
1 – ½ – ¼ – 1/8 - 1/16
Rhythm of beat
Advanced Settings
Pad setting / trigger
Press the Set button and this will open the Trigger settings.
Tap the trigger you want to edit (for example, the kick), and it will appear on the display.
Use the + and – buttons or the Central control knob to adjust the trigger settings. Press the Return button to
save the new settings and return to the previous menu.
Please note: If a parameter has been adjusted and the Return button has not been pressed, these changes
shall NOT be saved!
Trigger parameters:
Parameter
Value
Description
Sensitivity
0-31
Set the sensitivity of the pads/triggers for the optimum playing feel
Threshold
0-31
Only activate the trigger when a minimum value has been reached
Curve
Linear
Linear curve, where the strength at which the trigger is struck
determines the volume of sample
EXP1 /
EXP2
Exponential curve (where EXP2 gives the most extreme curve) where
a harder trigger strike has a more extreme effect on the volume of the
sample.
LOG1 /
LOG2
Logarithmic curves (where LOG2 is the more extreme curve), where a
lighter trigger strike has more effect on the volume of the sample.
SPLINE
Large volume difference between soft and hard trigger strikes.
LOUD1 /
LOUD2
Get a powerful volume when the trigger is struck lightly.
Dynamic Range
0-80
This controls the dynamic range of the trigger. The lower the value, the
less dynamic the reaction of the trigger. The higher the value, the more
dynamic the reaction of the trigger. You can experiment with your
playing dynamics by setting the Dynamic Range to a higher value.
Scan Time
0 – 4.0 ms
The Scan Time is a function that analyses the loudness at which a
sample should be played back depending on the way that the trigger is
struck. Since each trigger will not react in the same way, in some
cases it’s necessary to adjust the Scan Time a little more so that it’s
measured at a later peak-point during the strike. Try to keep this value
as low as possible.
Retrig Level
0-16
This setting determines the maximum time between the activation of
each trigger. Retriggering means that multiple triggers might be
All information and illustrations shown in this user manual are subject to change without further notice.
User manual version: 1.0
Creation date + author initials: 07-05-2020 RV Revision date + author initials: