13.6
Brix sample valve leaks. A. Damaged or failed o-rings
A. Turn off CO
2
, water and disconnect
on valve.
syrup. Depressurize by pressing
sample valve. Remove C-clip from
bottom of sample valve. Remove
sample valve shaft, change o-rings
and reinstall.
B. Inside hole of plastic header
B. Replace upper header block.
block is scratched or
damaged.
13.7
Low water pressure or
A. Water not turned on or line
A. Turn on water. Check for line
no water pressure.
restriction.
restrictions.
B. CO
2
not turned on or too low.
B. Assure CO
2
is turned on and verify
"CO2 Press" readout is 70-72 PSIG
(482.6-496.4 KPa).
C. Water pressure transducer
C. Verify "H2O Pressure" readout at
failure.
70-75 psi. Check transducer and
replace, if needed.
D. Water pump failure.
D. Check water pump and replace, if
necessary.
13.8
Noisy condenser fan.
A. Fan contacting condenser,
A. Remove fan guard and adjust fan
fan blade guard, or other
up or down as required. Remove
part.
obstruction as necessary. Reinstall
fan guard.
B. Fan blade not balanced.
B. Remove fan guard, slide fan blade
weights (on 3 blades) to balance
fan. Replace fan, if necessary.
Reinstall fan guard.
C. Loose fan bracket fasteners.
C. Tighten loose fasteners.
ELECTRICAL
13.9
Solenoids not activating. A. Solenoid plunger not lifting.
A. In “Manual On/Off”, energize
solenoid on and off checking for
plunger movement and 24VAC at
coil. Clean or replace solenoid, if
necessary.
B. Relay Board failure.
B. Test solenoid relay on Relay Board
for 24VAC output and 5VDC input.
Replace, if necessary.
C. Connectors not plugged in
C. Assure connections are clean and
at board or solenoid.
secure at P14 and solenoid coils.
13.10
Solenoids continuously
A. Solenoid plunger not dropping. A. In “Manual On/Off”, energize
activated.
solenoid on and off checking for
plunger movement and 24VAC at
coil. Clean or replace solenoid, if
necessary.
B. Solenoid Relay stuck.
B. Test solenoid relay on Relay Board
for 24VAC output and 5VDC relay
coil input. Replace, if necessary.
C. Transducer failure.
C. Observe "Tank Pressure" readouts
and check corresponding
transducer. Replace transducer, if
necessary.
13.11
Line voltage low
A. Low voltage to unit (below
A. Check voltage at L1 & L2 of
on LCD.
215 volts).
contactor and at wall receptacle.
Install Buck/Boost transformer, if
necessary (see Section 4).
B. Incorrect voltage offset.
B. Access “Machine Settings” menu
and adjust voltage offset so "Line
Voltage" readout equals L1 and
L2 contactor voltage. (see
Section 7.3).
(Item 13.11 continued on next page.)
22
TROUBLE
CAUSE
REMEDY