XL-20 Hookup and Installation Instructions
9–2
QUESTION 02
SECONDARY TELEPHONE NUMBER
DEFAULT = AAAAAAAAAAAAAAAA
Using the table in question 01 to determine valid digits, enter the telephone number
(including area code and/or dialing prefix, if necessary) of the secondary central station
receiver in L1 - L16.
The secondary telephone number will be used if the panel is unable to reach the central
station via the primary number. This is known as BACKUP reporting. If the SPLIT
REPORTING feature is programmed, then OPENING and CLOSING signals will be directed
to the secondary CS phone number only, while all other conditions will be reported to the
primary number.
If neither split nor backup reporting is necessary, this question may be left at the factory
default values and all conditions will be routed to the primary telephone number only.
QUESTION 03
CALLBACK TELEPHONE NUMBER
DEFAULT = AAAAAAAAAAAAAAAA
Using the table in question 01 to determine valid digits, enter the telephone number
(including area code and/or dialing prefix, if necessary) for this control panel to reach the
callback location. The callback number is the optional location of the EZ-Mate Downloader
where the control panel will call during a remote communications (upload/download etc)
session. During remote communications, the programming device and the control panel will
first confirm the CS security code. If it is valid, communications can begin. If you have
programmed a callback number, the control panel will the hang up and dial the callback
number.
NOTE: If you do not want callback capability, enter AAAAAAAAAAAAAAAA.
QUESTION 04
CS DIALER OPTIONS
DEFAULT = 0511
There are 4 locations (L1-L4) within this question, which define various dialer and system
options as follows:
Question 04, L1
CS Dialer Formats
Default = 0
Enter the digit for the desired dialer format from the table below in location L1.
Digit
CS REPORTING FORMAT
FORMAT TRANSMISSION TYPE
0
3X1 Standard
PULSE
1
4x1 Standard
PULSE
2
3x1 Extended
PULSE
3
4x1 Extended
PULSE
4
3x1 Partial Extended
PULSE
5
4x1 Partial Extended
PULSE
6
3x2
PULSE
7
4x2
PULSE
A
ADEMCO 4x2 Express *
DTMF
E
ADEMCO Point ID *
DTMF
NOTE: * These formats require a high/low handshake frequency
from the CS receiver.
For more information on CS reporting formats refer to Appendix A at the back of this manual.
Summary of Contents for XL-20
Page 9: ...XL 20 Hookup and Installation Instructions 1 2...
Page 19: ...XL 20 Hookup and Installation Instructions 4 2...
Page 23: ...XL 20 Hookup and Installation Instructions 5 4...
Page 33: ...XL 20 Hookup and Installation Instructions 8 4...
Page 63: ...XL 20 Hookup and Installation Instructions 11 4...
Page 65: ...XL 20 Hookup and Installation Instructions 12 2...
Page 71: ...XL 20 Hookup and Installation Instructions A 6...
Page 75: ...XL 20 Hookup and Installation Instructions B 4...
Page 77: ...XL 20 Hookup and Installation Instructions C 2...
Page 79: ...XL 20 Hookup and Installation Instructions D 2...
Page 81: ...XL 20 Hookup and Installation Instructions E 2...
Page 82: ...Notes...
Page 83: ...1 9 Gl N9825V1 04 98 Copyright 1998 PITTWAY CORPORATION...