XL-20 Hookup and Installation Instructions
9–8
Question 06, L1
Entry Delay 1
Default = 6
Enter the desired entry delay time for zones 1-3. Refer to Exit/Entry Times below for valid
choices. If zones 1-3 are delay zones, they follow Entry Delay 1. For UL applications,
the maximum Entry Delay shall not exceed 45 seconds for household applications or 15
seconds for commercial burglary applications. NOTE: See programming question 07, location
1 for Entry Delay 2.
Digit
ENTRY TIMEOUTS
0
1 SECOND
1
5 SECONDS
2
10 SECONDS
3
15 SECONDS
4
20 SECONDS
5
25 SECONDS
6
30 SECONDS
7
35 SECONDS
8
40 SECONDS
9
45 SECONDS
A
50 SECONDS
B
55 SECONDS
C
1 MINUTE
D
1 MINUTE 5 SECONDS
E
1 MINUTE 10 SECONDS
F
3 MINUTES
Question 06, L2
Exit Delay
Default = 6
Enter the desired exit time. NOTE: For UL applications, the maximum exit delay shall not
exceed 60 seconds.
Digit
EXIT TIMEOUTS
0
1 SECOND
1
10 SECONDS
2
20 SECONDS
3
30 SECONDS
4
40 SECONDS
5
50 SECONDS
6
1 MINUTE
7
1 MINUTE 10 SECONDS
8
1 MINUTE 20 SECONDS
9
1 MINUTE 30 SECONDS
A
1 MINUTE 40 SECONDS
B
1 MINUTE 50 SECONDS
C
2 MINUTES
D
2 MINUTES 10 SECONDS
E
2 MINUTES 20 SECONDS
F
3 MINUTES
Question 06 L3
Burglary Bell Cutoff
Default = 5
Enter the desired bell cutoff time on alarm conditions for burglary and panic in 3-minute
intervals (for example, 3 = 9 minutes). The valid range of input is 1 - F, with F indicating an
infinite burglary bell cutoff. For UL installations, the minimum bell cutoff shall be 15
minutes in commercial applications, or 6 minutes in household burglary applications.
Summary of Contents for XL-20
Page 9: ...XL 20 Hookup and Installation Instructions 1 2...
Page 19: ...XL 20 Hookup and Installation Instructions 4 2...
Page 23: ...XL 20 Hookup and Installation Instructions 5 4...
Page 33: ...XL 20 Hookup and Installation Instructions 8 4...
Page 63: ...XL 20 Hookup and Installation Instructions 11 4...
Page 65: ...XL 20 Hookup and Installation Instructions 12 2...
Page 71: ...XL 20 Hookup and Installation Instructions A 6...
Page 75: ...XL 20 Hookup and Installation Instructions B 4...
Page 77: ...XL 20 Hookup and Installation Instructions C 2...
Page 79: ...XL 20 Hookup and Installation Instructions D 2...
Page 81: ...XL 20 Hookup and Installation Instructions E 2...
Page 82: ...Notes...
Page 83: ...1 9 Gl N9825V1 04 98 Copyright 1998 PITTWAY CORPORATION...