Appendix A - Central Station Reporting Formats
A-5
KEYPAD ZONE TYPES (Fire,* Panic,*
Aux.,* Ambush)
Digit
EVENT
CODE
ENGLISH OUTPUT
AT CS RECEIVER
0
100
Medical
1
101
Pendant Transmitter
2
110
Fire Alarm
3
111
Smoke
4
112
Combustion
5
117
Flame
6
120
Panic Alarm
7
121
Duress
8
122
Silent Panic
9
123
Audible Panic
A
130
Burglary
B
133
24-Hour Alarm
C
140
General Alarm
D
150
24-Hour Non-Burg
E
115
Fire Pull Station
*NOTE: These keypad conditions have no
Zone/User code associated with them
BYPASS TYPES
Digit
EVENT
CODE
ENGLISH OUTPUT
AT CS RECEIVER
0
570
Zone Type Bypassed
1
571
Fire Zone Type
Bypassed
2
572
24-Hour Zone Type
Bypassed
3
573
Burg. Zone Type
Bypassed
4**
574
Point Group Bypass
DEDICATED CODES
EVENT
CODE
ENGLISH OUTPUT AT CS
RECEIVER
156
Day Trouble
301*
AC Loss
309*
Battery Test Fail
321
Trouble Bell
373
Fire Trouble
381
RF Supervision
383
RF Sensor Tamper
384
RF Low Battery
401
O/C by User
403
Auto Arm
406
Cancel on Open
407
Remote Arm
408
Quick Arm
409
Key Switch Zone Type
551
Dialer Disabled
602*
Test Periodic
*NOTE: These codes have no Zone/User
code associated with them; they will report
000 for these digits.
Summary of Contents for XL-20
Page 9: ...XL 20 Hookup and Installation Instructions 1 2...
Page 19: ...XL 20 Hookup and Installation Instructions 4 2...
Page 23: ...XL 20 Hookup and Installation Instructions 5 4...
Page 33: ...XL 20 Hookup and Installation Instructions 8 4...
Page 63: ...XL 20 Hookup and Installation Instructions 11 4...
Page 65: ...XL 20 Hookup and Installation Instructions 12 2...
Page 71: ...XL 20 Hookup and Installation Instructions A 6...
Page 75: ...XL 20 Hookup and Installation Instructions B 4...
Page 77: ...XL 20 Hookup and Installation Instructions C 2...
Page 79: ...XL 20 Hookup and Installation Instructions D 2...
Page 81: ...XL 20 Hookup and Installation Instructions E 2...
Page 82: ...Notes...
Page 83: ...1 9 Gl N9825V1 04 98 Copyright 1998 PITTWAY CORPORATION...