background image

Summary of Contents for XL4612RM

Page 1: ...XL 31 OWNERS MANUAL RE 8uRGURY INSTRUMENTS INC ...

Page 2: ...surface mounted in a back box XL 4612SM This is a surface mount keypad with 12 LEDs for monfiorfng zone status 7015 Keypad wtih a plastic case and with indisstor lights to show the statue of each of the zones NOTE Thie keypad displays zone status indication fights for 16 zones 7 Keypad with a plastic case and a two tine LCD tiquid crystal display with a two tine readout Please identify the keypad ...

Page 3: ...NDITIONS 15 DURESS 16 ARM NLY MAID CODE 17 DOORSTRIKE USERCODE 16 KEYPADTAMPER 19 QUICKARMING 20 QUICKFORCED ARMING 21 SET TIME OF DAY 22 ZONE DIRECTORY 23 SET AUTO ARM TIME 24 CHIME MODE 25 READ CLOCK TIME 26 READ AUTO SET TIME 27 DOOR STRIKE COMMAND 28 INSTALLATION UYOUT 29 SYSTEM TESTING FCC STATEMENT LIMITATIONS STATEMENT WARRANN 30 SUMMARY 31 OWNERS INFORMATION 4 5 6 6 0 9 9 9 10 10 11 11 12 ...

Page 4: ...ystem is running on AC ON or backup battery OFF If the Kghtis btinking slowly then the battery is low if it is bhnking rapidly then there is a telephone fine failure detected 4 READY ln cates whether the eystem is ready for arming ON Ready OFF Not Ready In addition the RDY fight shows the arming status if the ARMED LED is ON ae follows OFF Armed in Away mode Slow B nk Armed in STAY mode finterior ...

Page 5: ...NSTANT Indicates system is ARMED wtih all delay zonee instant 6 AC indicates system is running on AC ON or backup battery OF 7 BAT Indicates low battery Slow pulse low baffe OFF Noml 8 COM Indicates a communications failure with the Central station 9 NUMERICAL KEYPAD operates in a similar manner to a calculator or telephone with the dgits 0 9 and clearfy msked 10 OISPLAY AREA Ttis section of the L...

Page 6: ...m is ready ARMING can be performed as follow ARMING PROCEDURE 1 Enter your four digit user code into the keypad USER The ARMED inticator hghf will now be i and Hyou are leaving the home you may ex through a door designated by your installer as an extienfry zone for a fried time period known as the exit delay The entry exti times for your system are as follows ENTRY seconds EXIT seconds LCD keypads...

Page 7: ...ones are not ready byobsewing the zone indcator hghts or the display section of the LCD keypad From the zone number you can find out which area of protection ie not ready For example assume the zone 1 is not ready Typically ttis might mean that a protected door or window is own Oncethe problems wRheach zonehave beenresolved the R DY ghtwill appear and the eystem can be armed To ARM the system when...

Page 8: ... system arming they will appear on the dsplay The condtions that have occurred appear in the zone display section of the keypad LED based keypads will reflect the current syetem status through the indicator Iighta as follows ALARM Fastb nkmg BYPASS SlowbhnUnglow intens TROUBLE Slowpulse NOTREADY SohdON Burgla alarms will be indicated with a ST DY sound through the keypad while FIRE alarms will gen...

Page 9: ...splay will appear m In the STAY mde only the external or perimeter burglary protection is active You are free to walk around the residence without activating any of the infe r protection zones Remember you must DISARM the eyetem to when you want to leave the premiee Note The STAY oDtionwill automatically be reset after the eyetem is The lNSTANTmde arms the syetem and e minates the entry time delay...

Page 10: ...rom activating the securky system BYPASS PROCEDURE BYPASS USER ZN Depress the BYPASS key followed by your user code and two gif zone number 01 12 to be bypassed Example BYPASS USER 02 bypasses zone 2 If the zone has been bypassed already tha sequence will unbWass the zone except if the system is armed and the unbypassed zona is still not ready Unbypasa returns the zone to protected status After th...

Page 11: ... parameters USER DEFINITION PROCEDURE CODE USER US number USERID where CODE is the CODE key on the keypad USER maater ueer code User number 1or User number 2 four digite US number User number 01 30 USID New user ID 0000 9999 Notefi If ambush code capability has been enabled by your instal ng company then user number30 will be used as the eysfem ambush de If an arming on de maid code has been defin...

Page 12: ... of two keys as follows Hre 79 Aux 13 For example to initiate a keypad panic signal press the and keys at the same time Consult with your alarm installer to determine the operation of these conditions wittin your system In UL installations the AUX alarm is silent The XL4612SM keypad has keys for specially defined auxitiary functions Their fundions are activated by simultaneously depressing two key...

Page 13: ...selected by the inetaller this command 2 arms the system without entering a user mde and bypasses any unready burglary zones Quick forced arm 2 21 SET TIME OF DAY 3 The system contains a real time clock for the auto arming and system test capability The time of day can be set through any keypad using the following command 3 USER HR MN Time entry is performed in 24 hour time mititary time For examp...

Page 14: ...dify the auto arming time enten 5 USER HR MN For example change the auto arming time to 11 45 PM user de of 5678 entec 556782345 NOTE All times are entered in 24 hour mi ia time This feature is disabled in UL installations 24 CHIME MODE M The optional chime mode causes the keypad to beep for one second every time selected zones such as the entrance door are opened while the system is disarmed For ...

Page 15: ...ice your escape plan to assure that everyone knows what to do 6 Estabflsh a meeting place outside where your family is to re rt Once you have evacuated the house do not return to a burning house 7 Advise the local fire authority that you have installed a tire alarm system 8 When the fire alarm signals LWVE lMMEDfATELY Do not stop for belongings 9 If a fire occurs teef the door If hot use your ahem...

Page 16: ...m the system to silence the system and return to normal atatua BA ERY TEST In order to test the backup bafte the following promdure should be performed 1 Remove the AC transformer from the AC outlet by removing the restraining screw which secures tha transformer to the wall Note the screw is not present in mdels sold in Canada 2 Observe that the AC fight goes off on the keypad 3 Activate your alar...

Page 17: ...nto a dtierent outlet w that if and the radio or televisbn receiver are on diffarant branch circuits H necessary the user should mnauit the dealer or an experianmd radiohelavision technician for addtional suggestions The user may find the following hoklet prepared by the Federal timmunications mmisaion helpful Interference HandbooF This bklet is available fmm the U S Government Ptinting Offim Wash...

Page 18: ...hs in the Unfied States they may not activate or provide early warning for a variety of reasons in as many as 35 4 of all fires acmrdbrg to data pubfished by the Federal Eme ency Management Agency Some of the reaaons smoke detecfom used in conjunction wtih this System may not wok areas follows Smoke detectors may have been improperly installed ati psifioned Smoke detectors may not sense fires that...

Page 19: ... warning devices however loud my not warn hearing impaired people or waken deep sleepers Telephone hnes needed to transmit alarm signals from a premises to a central monitoring atafion maybe out of semice or tem rarily out of sewice Telephone tines are also subject to compromise by sophisticated intruders Even if the syetem responds to the emergency as intended however occupanfs may have inauffiii...

Page 20: ...ISPLAY CLOCK TIME SEQUENCE USER STAY USER INSTANT USER INSTANT STAY USER OR STAY INSTANT USER BYPASS USER Zn BYPASS Zn If zone is already bypaaaad USER CODE USER USER NUMBER USID CODE USER USER NUMBER 79 13 1 2 3 USER HH MM 4 5 USER HH MM 6 7 DISPLAY AUTO ARM T tiE 6 USER DOOR STRIKE 9 USER RIGGER NUMBER LCD KEYPADS ONLY NOTE If all of the LEDS on LED baaed keypads are btinting rapidly eve 30 sewn...

Page 21: ...LER BE LWSLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANW EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS QF LIABILIV WHATSOEVER EVEN THE LOSS OR DAMAGE IS CAUSED BY S OWN Negligence OR FAULT Somastates donotallow timk ion onhow long an implied warranty lasts or the exclusion or hmtiation of incidental or consequential damagas so the above Nmitationor ex...

Page 22: ...ION PERSONAL NAME ADDRESS CIW STATE ZIP TELEPHONE NUMBER EMERGENCY NUMBERS CENTRAL STATION FIRE DEPARTMENT POLICE DEPARTMENT NEIGHBOR GAS ELECTRiCCOMPANY DOCTOR HOSPITAL EMERGENCY SERVICEINFORMAnON AWRMINSTALLING COMPANY ...

Reviews: