• Click PARAM1 to confirm
• Click PARAM1 to confirm
• Rotate PARAM3 to the right to select characters
DEVICE NAME
The model of the machine is displayed by default, if you need to modify it
please follow the following order:
• Click the PARAM3 bu on
• Use the PARAM1 knob to select Network
• Rotate PARAM1 to Device Name
• Rotate PARAM2 to the right to select the edit character posi on
• Rotate PARAM2 to modify the character posi on and PARAM3 to select
the character; the maximum allowable 16 characters
• Enter to confirm the modifica on and return
SETTINGS
• Enter the name, PARAM1 select the character posi on, PARAM2 select
the character from the gallery below, the maximum allowable 16 characters
• A er the modifica on is completed, click PARAM1 to save.
NETWORK OPTIONS
The RS485 serial port can be set in the network op on menu and the
network se ngs of the machine can be viewed.
Under the se ngs, turn the PARAM1 knob, the last op on is the network
se ng, the network se ng is used to connect to the processor
management so ware and provides 3 different interfaces, namely USB,
RS485, LAN; among them the USB connec on is the easiest and the
installa on driver can be directly connected to the PC; RS485 needs to set
the serial port number, ID, baud rate, etc.. and need to be consistent with
the PC se ngs; LAN is suitable for mul ple processors or long distance
connec ons. Through the local area network, stable connec on quality and
high connec on speed can be obtained.
The DLM serie processors provide three connec on methods: USB,
RS485, TCPIP and you can choose any one of them to connect without
choosing.
UTILITY MENU:
Network Utilities
SET RS485 ID NUMBER
For example, the steps to set 485ID to 3 are:
When mul ple devices are connected via RS485 protocol, they need to be
set to different ID numbers and cannot be repeated. A er clicking
PARAM1, rotate PARAM2 to select ID numbers from 1 - 32.
• Click the PARAM3 bu on
• Click PARAM1 to confirm
• Rotate PARAM2 to the right to select 03
• Rotate PARAM1 to the right to select RS485 ID
• Click PARAM1 to confirm
• Use the PARAM1 naviga on knob to select Network
• Click PARAM1 to confirm
NETWORK UTILITY
RS-485 ID
RS-485 ID
SET ID=01
RS-485 ID
SET ID=03
PARAM. 1
Turning
NETWORK UTILITY
Device Name
Device Name
Name = DLM 260
ENTER
PUSH