SOFTWARE
For the FIR filter two modes can be selected, FIR+8 segment PEQ, FIR+IIR
high and low pass with a slope of up to -24dB + 4 segment PEQ.
You can use a simple FIR filter +8 segment PEQ or you can choose a FIR+IIR
mixed mode +4 segment PEQ. There are always a variety of solu ons that
are suitable for your use scenario.
Click Edit to enter the FIR edi ng op ons
Provides three guides of high-pass / low-pass / band-pass, you can enter
the frequency that needs to be band-passed according to your needs,
choose more or less taps, slopes from -20dB to -120dB/oct, and mul ple
window func on types. Click save at the red circle (here we use band pass
filter as an example).
If you need to use external FIR coefficient import, you can select "EXT" in
the red circle here, click enter to import FIR coefficient file.
Compa ble FIR convolu on so ware has been tested: rePhase, FIR
Designer, FIR Capture, Filter hose.
The FIR filter in the plug-in works at a sampling rate of 96kHz and a
maximum of 1536 taps.
External FIR supports three format of FIR coefficients, namely ".csv", ".txt",
".saf". The first two file formats can be generated by mainstream FIR
convolu on so ware and the ".saf" file can be saved and generated from
AEQ in the processor. It should be noted that the FIR filter in the input and
output part of the DLM series works at a sampling rate of 48kHz and a
maximum of 512 taps.
40