Program Limiter and “D-Max” Limiter
The SP27 units have two levels of dynamic protection on its outputs – a traditional program limiter, and a
newly introduced “D-Max” limiter.
High performance digital limiters are provided for each output with control over attack time, release time and
threshold parameters - see page for details. This level of control allows the user to balance the required
subjective quality of the limiter against the driver protection requirements. It does also mean that an
incorrectly set limiter may sound awful! In particular, as with all limiters, using too fast an attack or release time
will result in excessive low frequency distortion. In the
sub-menu there is an option for automatic
limiter time constants. Use this option if you are unsure how to set the time constants manually. It is
recommended the use of the automatic setting.
In this mode the time constants will be automatically set from the High-Pass filter frequency according to the
table below.
The time constants are set by the high pass filter frequency for that channel.
Program Limiter
DesignaCrossover
High Pass Filter
Auto Attack Time
Release Time
<10Hz – 31Hz
45mS
x16 (720mS)
31Hz – 63Hz
16mS
x16 (256mS)
63Hz – 125Hz
8mS
x16 (128mS)
125Hz – 250Hz
4mS
x16 (64mS)
250Hz – 500Hz
2mS
x16 (32mS)
500Hz - 1kHz
1mS
x16 (16mS)
1kHz – 2kHz
0.5mS
x16 (8mS)
2kHz – 32kHz
0.3mS
x16 (4mS)
28
ADVANCED AUDIO FEATURES
Summary of Contents for QUBE SP27
Page 1: ...QUBE SP27 Audio Management System www qubeaudio com FBT ELETTRONICA S p A www fbt it ...
Page 2: ......
Page 13: ...2 x 3 way crossover 1 x 6 way crossover 2 x 2 way mono 11 ...
Page 20: ...Menu System Overview 18 ...
Page 41: ...Appendix I SP27 Default Crossover Configurations 2 x 3 Way 39 ...
Page 42: ...2 x 2 Way Mono Sum 40 ...
Page 43: ...1 x 6 Way 41 ...