In cases where the barrel connector is not desired, you can use the alternate power input connector
(J4) which supports directly plugging in 20-26 AWG wire with maximum 5A current per contact. The
datasheet for this J4 connector (PCB terminal block - PTSM 0,5/ 2-2,5-H SMD WH R24 – 1814634)
can be found at
To verify that the ELI is correctly powered, you may check the 12VDC input with a Fluke meter or
scope by probing the +12V and GND contacts shown below. Please verify that the 12VDC is present,
is within the +/- 5% tolerance and is free from excessive noise or AC ripple.
Figure 3. ELI70-IPHW Power Test Points
Extended Display Information Data (EDID)
ELI uses Extended Display Identification Data (EDID) for automatic configuration with many
operating systems. You can find out more on our website at