For volume production applications, the input power can be optimized for your ELI unit and lower
capacity power supplies can be used.
In cases where the barrel connector is not desired, you can use the alternate power input connector
(J6) which supports directly plugging in 20-26 AWG wire with maximum 5A current per contact. The
datasheet for this J6 connector (PCB terminal block - PTSM 0,5/ 2-2,5-H SMD WH R24 – 1814634)
can be found at
To verify that the ELI101-IPHW unit is correctly powered you may check the 12VDC input with a
Fluke meter or scope by probing the +12V and GND contacts shown below. Please verify that the
12VDC is present, is within the +/- 5% tolerance and is free from excessive noise or AC ripple.
Once the HDMI cable has been plugged in, the LCD PWR LED (LED12) will illuminate orange to
indicate that power is applied, and an HDMI signal has been received by the ELI unit. This does not,
however, indicate that the HDMI signal is valid for the resolution of the ELI101-IPHW, just that the
HDMI signal is present.
Note: If using an input that is within the acceptable range of +5VDC to +24VDC (+/- 5%),
please keep in mind that the 12V Test points should be at the voltage of your chosen power
supply (5-24VDC).
Figure 5. ELI101-IPHW Power Test Points
LCD Power LED
(LED12)