background image

MLED-CTRL Box 

User manual 

 

 

 

December 2021 - Version EN 1.2 

www.fdstiming.com

 

                                                        

 

2.5.

 

Counter Mode 

-  This mode works either with the external Jack inputs 1 & 2, or with WIRC signals. 
-  User can chose between 1 or 2 counters and several predefined counting sequences. 
-  For single counter, Jack input 1 or WIRC 1 is used for counting up and Jack input 2 or WIRC 

2 for counting down. 

-  For dual counter, Jack input 1 or WIRC 1 is used for Counter 1 count up and Jack input 2 or 

WIRC 2 for Counter 2 count down. 

-  Depressing and holding for 3 seconds a jack input will reset the corresponding counter to 

its initial value. 

-  All parameters as inputs lock time, initial value, 4 digits prefix, counter color can be set 

using the Menu Buttons or via our setup Apps. 

-  WIRC 1&2 can be paired using the Menu Buttons or via our setup Apps. 
-  Settings allow the possibility to hide the leading ‘0’. 
-  If RS232 protocol is set to “DISPLAY FDS”, then each time the counter is refresh, a Display 

frame is send on the RS232 port. 

 

2.6.

 

Count-Down Mode 

-  This mode works either with the external Jack inputs 1 & 2, or with WIRC signals. 
-  Jack input 1 or WIRC 1 is used to start/stop the countdown. 
-  Jack input 2 or WIRC 2 to reset it to its initial value. 
-  All parameters as inputs lock time, initial value and counter color can be set using the 

Menu Buttons or via our setup Apps. 

-  WIRC 1&2 can be paired using the Menu Buttons or via our setup Apps. 
-  Settings allow the possibility to hide the leading ‘0’. 
-  Text color can be defined for 3 segments.  

Segment 1 starts at the initial counter value.  
Segments 2 and 3 threshold are defined by the user. 

-  A beep is generated 10 seconds before the end of countdown, then from 5 seconds: 1 beep 

every second. Reaching zero a long beep with higher tone is generated. 

-  After a reset, the pre-defined counter value can either be displayed right away or hidden 

until the next start. 

-  A time frame is sent on the RS232 port when the counter reach zero. 

 

 

Summary of Contents for MLED-3C

Page 1: ...tion comprises of 3 or 4 x MLED panels adjoined to form a display fully configurable to either a single full height line of characters or multiple lines as below Another configuration proposed is 2 ro...

Page 2: ...es can be selected and configured either via our iOS or PC setup application The first two modes are part of the basic firmware Modes 3 6 belong to a 1st optional group and require an activation key t...

Page 3: ...olution or with WIRC wireless photocells signal Two input sequence modes are available a Sequenced mode Normal On receiving an impulse on jack input 1 or wirelessly via WIRC 1 the running time starts...

Page 4: ...n impulse on jack input 2 or wirelessly via WIRC 2 finish time is recorded Speed is then calculated using the time difference and distance and displayed b No sequenced mode Any Inputs Start and Finish...

Page 5: ...If RS232 protocol is set to DISPLAY FDS then each time the counter is refresh a Display frame is send on the RS232 port 2 6 Count Down Mode This mode works either with the external Jack inputs 1 2 or...

Page 6: ...ant parameters should be configured Before countdown After initial power up the display enters a wait for synchro state The default synchro is defined in the settings Other synchronization methods can...

Page 7: ...is set according to the sectors definition Every second a light is turned on until zero is reached E Cnt 2 Lights Full size countdown value is displayed max 4 digits as well as 1 traffic light on each...

Page 8: ...ycles time interval Time between each countdown cycle This value must be equal or greater than the countdown value plus the end of countdown time Countdown value Countdown time in seconds Countdown co...

Page 9: ...ttings EXT INPUTS Parameters of the 2 external inputs Jack connectors RADIO Radio settings and WIRC wireless photocell pairing EXIT Leave the menu General Settings DISP INTENSITY Change the default di...

Page 10: ...NT RESULTS Print the time result if RS232 Protocol is set to Printer EXIT Leave the menu Mode Settings Speed Mode DISTANCE Set the distance DISTANCE UNITS Select the distance unit meters or feet SPEED...

Page 11: ...e way countdown info are displayed SYNCHRO Perform a new synchro GPS or manual PRINT SETTINGS Print the settings if RS232 Protocol is set to Printer EXIT Leave the menu CntDown Param Start Clock Mode...

Page 12: ...ia our setup Apps Important Do not use a same WIRC WINP WISG on a Display and a TBox simultaneously 4 1 Factory settings Factory settings can be restored by pressing both Menu Buttons on MLED CTRL dur...

Page 13: ...d together 5 3 Input_1 Temperature sensor Input This 3 5mm jack connector combines 2 functionalities 1 Time capture input 1 2 Digital temperature sensor input 1 External input 1 2 Temperature Sensor D...

Page 14: ...RS232 RS485 Any standard RS232 DSUB 9 cable can be used to drive the MLED Ctrl from a computer or other compatible device On the connector 2 pins are reserved for RS485 connection DSUB 9 female pinout...

Page 15: ...8bits no parity 1 stop bit Baud Rate 9600bds 6 2 Characters Set All standard ASCII characters 32 126 excepted for the char which is used as delimiter 0123456789 ABCDEFGHIJKLMNOPQRSTUVWXYZ _ abcdefghij...

Page 16: ...lor overlay between two characters position permanent cp cmd s first character position 1 32 e last character position 1 32 c color code Example STX 13 cp 1 10 2 cp 11 16 3 LF Characters position 1 to...

Page 17: ...mand Description fi c Fill with a defined color the full display area Only 50 of the LEDs are turned on to reduce current and heating fi cmd c color code Example STX 13 fi 1 LF Fill the display line w...

Page 18: ...ort f Select the update file bin g Press Start on the program h Connect the power cable to MLED CTRL Box MLED module firmware can also be updated via the MLED CTRL Box using the same procedure Firmwar...

Page 19: ...s or discrepancies between this manual and the product described The sale of products services of goods governed under this publication are covered by FDS s standard Terms and Conditions of Sales and...

Reviews: