background image

TBox-1x & TBox-2x User manual 

 

 

 

September 2017 - Version EN 1.1 
www.fdstiming.com

 

                                                        

 

 

3.

 

Power Status LED 

 

 

TBox On/Off

 

USB

 

Battery

 

Yellow ON

 

OFF

 

connected

 

Battery Charging

 

Green ON

 

OFF

 

connected

 

100% charged

 

Yellow blinking

 

ON

 

connected

 

Battery Charging

 

Green blinking

 

ON

 

connected

 

100% Charged

 

Green blinking

 

ON

 

disconnected

 

> 25%

 

Red blinking

 

ON

 

disconnected

 

Low battery

 

 

 

4.

 

Timing Inputs 

The TBox models 1x, 2x offers 4 inputs.

 

 

 

Manual Push Buttons (inputs 1 to 4)

 

 

Jack-Mono inputs (inputs 1 to 4)

 

- Working contact without potential (short-circuit)

 

 

Each press of the button or short-circuits on the Inputs are stored in the TBox memory, with 

associated date and time of impulse as CSV files.

 

 

The user has the ability to configure a locking time using the “TBox-Setup” app. This facility 

allows the blocking of undesired impulses corresponding to the channel configured.

 

E.g. – to ignore multiple inputs from dirt or snow dust

 

 
 

5.

 

Mini-USB 

The Mini-USB connector has various functions including: 

 

 

External power supply and battery charging 

 

COM port emulation for RS232 communication and data transfer 

- Real time of day in many formats (FDS, TAG Heuer, Alge, Seiko) 

- Configure the TBox options and parameters (with the app “TBox-Setup”) 

 

2GB USB Flash Drive 

- All impulse data are stored in a .csv file on the drive. A new file is created every time 

the TBox is swiched ON 

- User needs to maintain sufficient memory availability to ensure storage of impulse 

data

 

- The space required for a competition of 1000 times is approximately 40 Kbytes

 

 

 

 

Reviews: