Glass Information:

1.

Under no circumstances should this product be operated with broken glass.

2. Do not strike or slam the glass.
3. Do not use abrasive cleaners to clean the glass.
4. This product uses tempered glass. Replacement of the glass supplied by the manufacturer should be done by 

a qualified service person.

Light Bulb Inspection and Replace:

1.

The flame effect is created by two 40-Watt light bulbs with an E-12 (small) socket base. Use only this type of 

light bulb. If the flame effect does not work, the bulbs may have come loose or been damaged during 

shipping.

2. CAUTION: Light bulbs become very hot during use. Allow at least 10 minutes for the bulbs to cool before 

touching.

3. To inspect or replace the bulbs, first unplug the power cord from the outlet. Locate the access panel on the 

back of the stove. Remove the screws and the panel. Check the bulbs to be sure they are finger tight and in 

working order. Replace any damaged or faulty bulbs. Reattach the access panel. Do not operate this heater 

without the access panel in place. Do not remove the back cover of this heater. There are no serviceable 

parts inside.

4. WARNING: Do not exceed 40 watts per bulb. Use of higher rated bulbs may result in a fire, causing property 

damage or personal injury.

Motor Maintenance:

Always disconnect the appliance from the main power supply and allow it to cool before any servicing operation.

The motors used on the fan heater and flame blower are pre-lubricated for extended bearing life and require no 

further lubrication. However, periodic cleaning/vacuuming of the appliance around the air intake and exhaust, as 

well as the fan heater is recommended. For heavy or continuous use, periodic cleaning must be done more 

frequently. If the heater blows alternating cold and warm air, check the fan for free movement and for debris 

restricting air flow. If the fan does not move freely, the unit must be turned off and the fan replaced immediately in 

order to prevent further damage to the unit. 

Do not strike or slam the glass.

Care & Cleaning

Always turn the stove OFF and unplug the power cord from the outlet before cleaning. Use a vacuum or 

duster to remove dust and dirt from the heater and vent areas. To maintain the finish, clean with a soft, 

slightly damp cloth and buff with a dry cloth. Never use abrasive cleansers, liquid sprays, or any cleaner 

that could scratch the surface.

WARNING:  Before attempting to perform any maintenance on this appliance, turn all controls to the “OFF” 
position and then unplug. Allow the appliance to be “OFF” for at least 10 minutes before performing any 
maintenance in order to allow all components to cool properly. 

MAINTENANCE

ITEM#810469828

SKU#F19-C-041-138

Summary of Contents for F19-C-041-138

Page 1: ...ANY PRODUCT TO STORE FOR ANY MISSING PARTS HARDWARE OR ASSEMBLY PROBLEMS PLEASE CONTACT WITH OUR CUSTOMER SERVICE CENTER AT 1 877 355 3326 WORKING HOURS MONDAY FRIDAY 9 00AM 4 00PM PACIFIC STANDARD T...

Page 2: ...not use outdoors 9 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never place this appliance where it may fall into a bathtub or other water container 10 D...

Page 3: ...e the risk of fire electrical shock and injury to persons Do not use this item if any part of it has been under water Immediately call a qualified service technician to inspect the item and replace an...

Page 4: ...VE DIMENSIONS TOOLS REQUIRED Phillips screwdriver not included ITEM 810469828 SKU F19 C 041 138 Ref EST 425T 10 A 12 72 in 32 3 cm B 28 32 in 71 94 cm C 25 in 63 5 cm tions Voltage Frequency Amps Rati...

Page 5: ...on missing parts or damage please contact the Customer Service Team at 1 877 355 3326 DO NOT dispose of packaging until you are satisfied with your stove DO NOT return the unit to the store before cal...

Page 6: ...the 15 amp 120 volt outlet Never use a re locatable power tap outlet power strip ITEM 810469828 SKU F19 C 041 138 Clearance to Combustibles Sides 4 in 101 6 mm Floor 0 in 0 mm Top 36 in 914 mm Front 3...

Page 7: ...ust be in the ON position for any functions to work Flame Effect Toggle the Power Switch ON The Power indicator light will glow The flame effect will be visible through the front glass Temperature Kno...

Page 8: ...e or personal injury Motor Maintenance Always disconnect the appliance from the main power supply and allow it to cool before any servicing operation The motors used on the fan heater and flame blower...

Page 9: ...ctrical Code ANSI NFPA NO 70 3 If repairing or replacing any electrical component or wiring the original wire routing color coding and securing locations must be followed WARNING Before attempting to...

Page 10: ...e light bulb s 3 There are burnt out light bulb s 1 Refer to the operating instructions 2 Tighten the light bulb s 3 Replace the light bulb s The heater is not operating 1 The stove is not operating c...

Page 11: ...anty limitations may not apply to you This limited warranty gives you specific legal rights You may also have other rights which vary from jurisdiction to jurisdiction Repair or replacement at FEBO s...

Reviews: