6.3 Input and Output Testing Menu
The 4 inputs, BMS input and 3 relays, 3 channel, Windsock and Beacon relays can all be tested
through the Input/Output Testing menu.
These tests are extremely useful during installation to check that all of the interface
In the lower left screen above input 1 has been made
active and is shown in line 4 as ‘On’.
6.3.1 Test Relays
From the Test Relays Menu either the Channel relays or the Windsock and Beacon relays can be
tested.
6.3.1.1 Test Channel Relays
Pressing F1, F2 or F3 toggle the three relays 1
– 3 respectively. As the relays are activated a
‘clunk’ should be heard from the unit. The coil currents of these relays are measured to ensure
there is continuity in the circuit. A figure of 100 +/-10mA should be displayed for the active relays.
When de-activated they can be heard disengaging.