1

SERIES  NOMENCLATURE

A F P B 24 A 1 * A

Product Type

A = Air handler

Nominal BTUH

18 = 18,000 BTU/H (5.28 kW)

24 = 24,000 BTU/H (7.03 kW)

30 = 30,000 BTU/H (8.79 kW)

36 = 36,000 BTU/H (10.55 kW)

42 = 42,000 BTU/H (12.31 kW)

48 = 48,000 BTU/H (14.07 kW)

60 = 60,000 BTU/H (17.58 kW)

Brand

Electrical Designation

1 = 208 / 230 Volts, 1Phase, 60 Hz

2 = 230 Volts, 1 Phase, 50 Hz

3 = 208 / 230 Volts, 3 Phase, 60  Hz

4 = 460 Volts, 3 Phase, 60 Hz

5 = 230 Volts, 3 Phase, 50 Hz

6 = 380 Volts, 3 Phase, 50 Hz

Design Series

Revision Letter

Motor

E = ECM

P = PSC

Chassis Size 

B = 43 3/8” H x 18” W x 22” D

C = 48 1/8” H x 22” W x 26” D

RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS

What You Need To Know About Safety Instructions

Warning and Important Safety Instructions appearing in this
manual are not meant to cover all possible conditions and
situations that may occur. Common sense, caution and care
must be exercised when operating or cleaning tools and
equipment.

Always contact your dealer, distributor, service agent or
manufacturer about problems or conditions you do not
understand.

DANGER

indicates an imminently hazardous situation which,

if not avoided, will result in death or serious injury.

This is the safety alert symbol. It is used to alert you to

potential personal injury hazards. Obey all safety messages
that follow this symbol to avoid possible injury or death. 

WARNING

indicates a potentially hazardous situation which,

if not avoided, could result in death or serious injury.

CAUTION

indicates a potentially hazardous situation which, if

not avoided, may result in minor or moderate injury.

CAUTION

used without the safety alert symbol indicates

a potentially hazardous situation which, if not avoided,
may result in property damage.

DANGER

WARNING

CAUTION

CAUTION

WARNING

IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE INJURY, PROPERTY DAMAGE OR LOSS OF LIFE.
READ THIS MANUAL COMPLETELY BEFORE
BEGINNING ANY WORK AND FOLLOW ALL SAFETY
PRECAUTIONS.

A

QUALIFIED INSTALLER MUST PERFORM

INSTALLATION AND SERVICE.

DO NOT DESTROY THIS MANUAL. PLEASE READ
CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE
REFERENCE BY A SERVICE TECHNICIAN.

THESE INSTRUCTIONS ARE INTENDED AS AN AID TO
QUALIFIED SERVICE PERSONNEL FOR PROPER
INSTALLATION, ADJUSTMENT AND OPERATION OF
THIS COMPONENT. READ THESE INSTRUCTIONS
THOROUGHLY BEFORE ATTEMPTING INSTALLATION
OR OPERATION. FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY RESULT IN IMPROPER
INSTALLATION, ADJUSTMENT, SERVICE OR
MAINTENANCE, POSSIBLY RESULTING IN FIRE,
ELECTRICAL SHOCK, PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH. 

B E F O R E   P E R F O R M I N G   A N Y   W O R K   O N   T H I S
EQUIPMENT, POWER SUPPLY MUST BE TURNED OFF AT
T H E   H O U S E H O L D   S E R V I C E   B O X   T O   A V O I D   T H E
P O S S I B I L I T Y   O F   S H O C K ,   I N J U R Y ,   D A M A G E   T O
EQUIPMENT, OR DEATH.

DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS, OR OTHER
COMBUSTIBLE MATERIALS IN THE VICINITY OF THIS
AIR HANDLER OR ANY OF ITS MATCHING SYSTEM
COMPONENTS (CONDENSING UNIT, HEAT PUMP OR
FURNACE).

Summary of Contents for AFPB24B1

Page 1: ...ing 6 Factory and Field installed Expansion Valves 6 Ductwork 7 Return Air Ducting 7 Return Air Platform Height 7 LINE VOLTAGE CONNECTIONS 7 24 VOLT CONTROL SYSTEM 8 CONDENSATE PLUMBING 8 WIRING DIAGR...

Page 2: ...ion which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without th...

Page 3: ...ndividuals specially trained and experienced in the installation of this type equipment and related system components Installation and service personnel are required by some locales to be licensed Per...

Page 4: ...E DUCT 600 FPM 24 MINIMUM RETURN GRILLE 500FPM RETURN PLATFORM LINED WITH 1 FIBERGLASS INSULATION REFER TO LOCAL CODES CLOSET AIR HANDLER Upflow Installation With Return Duct DISCHARGE DUCT 600 FPM 24...

Page 5: ...rom left hand side of air handler and re install on right hand side Change splash baffle location from left hand to right hand side of drain pan flange 4 Remove the horizontal coil support bracket fro...

Page 6: ...filter grille may be installed for closet applications If this method is not desirable cabinet extension kit No 65 1647 for A24 A30 and A36 or No 65 1649 for A42 A48 and A60 may be ordered The extens...

Page 7: ...BE TAKEN TO AVOID OVERHEATING THE TXV VALVE AND CAUSING DAMAGE TO THE INTERNAL COMPONENTS 3 Attach the bulb securely with the copper strap provided 4 Insulate the bulb thoroughly with a suitable insu...

Page 8: ...4 2 5 163 8 41 6 221 4 56 5 3 7 6 3 7 6 13 4 4 4 2 5 163 8 41 6 221 4 56 5 3 7 6 3 7 6 13 4 4 4 2 5 11 8 WARNING BEFORE PERFORMING ANY WORK ON THIS EQUIPMENT POWER SUPPLY MUST BE TURNED OFF AT THE HOU...

Page 9: ...ING IMPROPER INSTALLATION OF THE ELECTRICAL WIRING OR THE HEAT ASSEMBLY MAY RESULT IN FIRE SERIOUS PERSONAL INJURY OR DEATH UNIT FLEXIBLE TUBING HOSE OR PIPE DRAIN CONNECTION A POSITIVE LIQUID SEAL IS...

Page 10: ...0 5 3 10 5 3 kW does not include motor watts Ampacities and over current protection based on largest air handler motor load Refer to specific name plate for exact ampacity and overcurrent protection s...

Page 11: ...1 4 3 5 8 13 1 4 15 48 1 8 19 1 8 21 26 22 16 3 8 22 1 4 AFPC48B1 2 1 4 3 5 8 13 1 4 15 48 1 8 19 1 8 21 26 22 16 3 8 22 1 4 AFPC60A1 2 1 4 3 5 8 13 1 4 15 48 1 8 19 1 8 21 26 22 16 3 8 22 1 4 AFPC60B...

Page 12: ...30 1840 1770 1590 LOW 20 kW 0 35 15 kW 0 35 1360 1350 1340 1185 1080 Air flow shown at the following conditions No heat elements in air handler Decrease CFM 1 for 5 kW 7 5 kW or 10 kW heat kits Decrea...

Page 13: ...ompartment remove the cover plate from the element housing Remove cover plate Remove air handler field wiring box and discard Remove two screws 11 14 11 15 5 Cut the wire tie holding the heater plug a...

Page 14: ...other than 230 multiply temperature rise by capacity correction factor Refer to CFM tables to determine Cfm at total external static pressure in system For correction of unit output multiply the corr...

Page 15: ...TATIONS Limited Warranty does not include allowances for labor or travel expense connected with the installation of parts so furnished in this Limited Warranty or for field repair or servicing of the...

Page 16: ...r the general appearance of the units at the time of publication and the manufacturer reserves the right to make changes in design and construction at any time without notice For replacement parts ple...

Reviews: