background image

 

THE CARTRIDGE FILTER 

 

CAUTION

:  Before servicing any portion of 

the air cleaner: 
 
1. Disconnect the electrical power. 
 
2. 

Shut off and bleed the compressed air  

 

  

 

 

supply. 

 
The backflushing process may lose effectiveness 
on removing collected contaminants after ex-
tended use.  (The filter life may be extended by 
removing the filter from the cabinet and manually 
directing compressed air into the center of the 
filter to dislodge contaminants.) 

 

 
TO REMOVE AND REPLACE FILTER 

 

NOTE: Depending on the contaminant col-
lected, it may be advisable to wear a dust res-
pirator when handling dirty filters. 

 

1.  Open filter access cover. 
 
2.  Move cartridge filter slightly up and down to 

break the rear gasket seal. 

 
3.  Rotate the cartridge 1/2 turn to permit any 

loose contaminant falling from the top of the 
elements. 

 
4.  Slide the cartridge filter out of the compart-

ment. 

 
5.  Clean any dust deposits from the rear gasket 

seal area to assure a positive seal for the 
replacement cartridges. 

 
6.  Remove excess contaminant from bottom of 

compartment by brushing out or by vacuum-
ing. 

 
7.  Install new cartridge and replace access 

cover.  

 

WARNING ! 
 
Electric Shock Hazard 
Can Cause Personal Injury or Death

 

 

LIMITED WARANTY 

 

Trion warrants the equipment of its manufacture 
to be free from defects in workmanship and ma-
terial for a period of 36 months after shipment. 
This warranty is limited, however, to the repair or 
replacement of defective equipment, which is 
returned, freight prepaid, to manufacturer’s fac-
tory.  This warranty does not cover any of the 
replacement filters in the unit, i.e. cartridge filter, 
HEPA (optional), Impregnated after filter. 
 
This limited warranty does not apply to any part 
or component that is damaged in transit or when 
handling, has been subject to misuse, negli-
gence or accident, has not been installed, oper-
ated or serviced according to Seller's instruc-
tions, or has been operated beyond the factory 
rated capacity or has been altered in any way. 
 
Trion’s liability is limited to replacement of defec-
tive parts or components and does not include 
any cost of labor (including, but not limited to, 
labor required to remove and/or reinstall any de-
fective part) other than Trion factory labor. 

 

Trion shall not be responsible for loss of use of 
any product, loss of time, inconvenience, or dam-
age to other equipment or any other indirect or 
consequential damage with respect to property 
whether as a result of breach of warranty, neglect 
or otherwise. 
 

THE WARRANTIES AND LIABILITIES SET 
FORTH ABOVE ARE IN LIEU OF ALL OTHER 
WARRANTIES AND LIABILITIES, EXPRESSED 
OR IMPLIED, IN LAW OR IN FACT, INCLUDING 
ANY IMPLIED WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR PARTICULAR 
PURPOSE. 

 
The foregoing shall constitute the total liability of 
Seller in the case of defective performance of all 
or any of the equipment or services provided to 
Buyer. Buyer agrees to accept and hereby ac-
cepts the foregoing as the sole and exclusive 
remedy for any breach or alleged breach of war-
ranty by seller

Summary of Contents for Trion PORT-A-CART

Page 1: ...PORT A CART Portable Cartridge Air Cleaner INSTALLATION OPERATION SERVICE For Industrial Applications www trioninc com Manual Part Number 157199 001 March 2004...

Page 2: ...Cleaning 5 Optional Pulse Cleaning 5 Recommended Operating Range 5 The Cartridge Filter 6 To Remove and Replace Filter 6 Warranty 6 Troubleshooting Guide 7 Figure 1 Wiring Diagram 8 Figure 2 Outline D...

Page 3: ...r the source of pollutants adjust the arm and place the cast ers in the locked position Then connect the electrical power and the unit is ready for op eration In operation the pick up arm delivers the...

Page 4: ...he collection of any materials where there is a risk of explosion Pressure relief or explosion vents should not be applied to the equipment or any adjoin ing system 3 Equipment location installation a...

Page 5: ...ray located below the filter When the filter cleaning is complete the dust tray may need to be emptied Return the unit to operation by reattaching the filter access cover and opening the damper in the...

Page 6: ...nt of defective equipment which is returned freight prepaid to manufacturer s fac tory This warranty does not cover any of the replacement filters in the unit i e cartridge filter HEPA optional Impreg...

Page 7: ...rm Remove obstruction Backflush manually clean or replace Remove obstruction Optional cleaning system not cleaning filters Faulty air diaphragm Shop air pressure Check to insure internal air line is i...

Page 8: ...8 Figure 1 Wiring Diagram...

Page 9: ...9 Figure 2 Outline Diagram...

Page 10: ...wer Wheel 5 1 256941 001 Impregnated Carbon Filter 6 1 256950 002 Power Cord 7 1 238001 002 Toggle Switch DPST 8 8 245386 017 Latch 9 2 252122 001 Caster 5 Fixed 10 2 252122 002 Caster 5 Swivel 11 1 3...

Page 11: ...11 Figure 3 Parts List Diagram...

Page 12: ...Fedders International Boscstr 60 No 728 Fuzhou Rd D 50171 Kerpen Rm 3002 3005 Germany Raffles City Office Tower Tel 49 0 2237 922 103 Shanghai P R China 200001 Fax 49 0 2237 922 104 Tel 86 21 63403232...

Reviews: