44
• Setting the DIP Switches
ZMA-330, Ver.6
PosiDRIVE Security Gate
DIP Switch 7: Backout Gate Arm Timeout
The following table lists the DIP switch positions to enable or disable Backout
Gate Arm Timeout.
DIP Switch 8: Auto-Raise
The following table lists the DIP switch positions to enable or disable the auto-
raise function.
Table 2-6 —
Backout Gate Arm Timeout DIP Switch Settings
Values
DIP Switch Positions
Backout Gate Arm
Timeout disabled - gate
arm stays up until
vehicle clears loop B
DIP switch 7 open
Backout Gate Arm
Timeout enabled - gate
arm closes after time
specified with DIP
switches 3 and 4
elapses if vehicle is not
detected on loop B
DIP switch 7 closed
Table 2-7 —
Auto-Raise Function DIP Switch Settings
Values
DIP Switch Positions
Automatically raise gate
during a power failure
DIP switch 8 open
Do not raise gate during
a power failure
DIP switch 8 closed