PosiDRIVE Security Gate
ZMA-330, Ver. 6
Locking, Unlocking, and Advancing the Gate Arm •
51
3.
Push the motor crank hinge, shown in Figure 3.1 and Figure 3.2, to advance the
mechanism out of the locked position.
Figure 3.1
Motor Crank Position when the Gate Arm is Down
Figure 3.2
Motor Crank Position when the Gate Arm is Up
4.
Manually raise or lower the gate arm as far as possible.
5.
Pull the motor crank to lock the drive mechanism linkage. When locked, the hinges
in the linkage are aligned.
If the mainsprings are not installed, locking the gate arm when it is in
the up position is especially important to avoid serious injury.
Point at which you can move
the mechanism to manually
advance the gate arm out
of the down position
To prevent a serious pinching injury including dismemberment, use
care when working with the drive mechanism and alway terminate
power prior to performing maintenance or repairs.
Point at which you can move
the mechanism to manually
advance the gate arm out of
the up position