- 31 -
REFRIGERATION & ELECTRICAL DATA
REFRIGERATION AND ELECTRICAL DATA
REFRIGERANT TOTAL AMPS
134A (OZ)
NON REFRIGERATED
CD3628/CD3628SS
N/A
1.5
CD4828 & CD4828SS
N/A
1.5
REFRIGERATED SELF CONTAINED
CRB3628/CRR3628
18
8.1
CRB4828/CRR4828
18
8.3
CRR3628SS/CRR3628SS
20
8.1
CRR4828SS/CRR4828SS
20
8.3
REFRIGERATED REMOTE
CRB3628R/CRB3628SSR
N/A
3.6
CRB4828R/CRB4828SSR
N/A
3.8
CRR3628R/CRR3628SSR
N/A
1.5
CRR4828R/CRR4828SSR
N/A
1.5
MAIN WIRING DIAGRAMS
DRY, SERVICE AND SELF SERVE CASES (120VOLT) - BEFORE 9/18
BLK
G
SHEL LIGHT
LAMP
G
TOP LIGHT
LAMP
BLK
B
R
B
B
R
B
R
W
BLK
(B
LK
)
B
BLK
(S2)
G
SHELF
LIGHT
LAMP
BLK
B
R
W
BALLAST
BLK (SWITCH)
LIGHT
SWITCH
BLK
BLK
(BALLAST)
(BALLAST)
(B
A
LL
A
S
T
)
(S
1)
B
R
B
R
G
COLOR CODE
B = BLUE
Y = YELLOW
W = WHITE
R = RED
BLK = BLACK
G = GREEN
G
R
PLUG & CORD 120 V, 60 HZ, 1 PH
(T
)
(W
)
(G
)
91-17144 10/21/02
(SWITCH)