IMSS E3265
- 26 -
Control Factory Settings
The control parameters are set at the factory and cannot be manually changed in the
field. Control parameter changes can only be made by downloading a new set of
parameters via a program chip supplied by Federal Industries
E3380
AS OF:
11/10/11
TAB
REF
PARAMETER
DESCRIPTION
FACTORY
DEFAULT
ECSS40/60,
IMSS60/84
CONFIGURATION
1
Controller
Operation
Temperature
Units
Fahrenheit
ºF
4
Defrost
Termination
Method
Evaporator
Sensor
Evaporator
Sensor
SET-POINTS
8
Cut-In Warm
14ºF
41ºF
9
Cut-Out Warm
-4ºF
28ºF
10
Cut-In Cold
-2ºF
41ºF
11
Cut-Out Cold
13ºF
13
Comp
Minimum On
Time
1 min
5 min
0 sec
DISPLAY
15
Defrost Display
Lock (display
indication
during defrost)
Lock
Display at
Temp.
reading
prior to
defrost.
SHOW
CURRENT
TEMPERATURE
DEFROST
38
Defrost
Termination
Temperature
41ºF
43ºF
39
Time to First
Defrost
(hh:mm)
6 hr
8 hr
40
Time to
subsequent
Defrost
6 hr
8 hr
41
Defrost Max
Duration
1 hr
30 min