Removing Case From Shipping Skid
Remove the screws and brackets that secure the case to the skid. Remove the
brackets from the case.
Note that the case may have optional wheels installed and once the brackets
holding the case to the skid are removed the case will roll.
Removing Packaging Material
Remove bubble wrap and packing material for all shelves and panel, brackets,
etc. If it is necessary to remove tape residue from plastic materials, use cleaning
compounds recommended in the cleaning section of this manual.
Leveling The Case
The case must be level for proper drainage of defrost water to the condensate
pump. A wrench is included to aid in adjusting leg levelers
Check the level of the case where the display overhangs the base.
Adjust the (4) outside leg levelers as needed to level the case in each direction.
The IMSS120 has (2) center leg levelers adjust these so that the center of base
floor is flat.
NOTE: Use a wood or plastic shim under each leg leveler to avoid scratching the
tile floor.
CAUTION
:
Do not push against the clear acrylic deflector around the sides and nose.
Doing so can cause the acrylic to break.
Do not lift or push on the top canopy located on top of the case.
Doing so can permanently damage the tower frame.
Care must be taken not to damage or tip the case when removing it from the
skid or moving the case.