Wiring the LED Message Board System in the Vehicle

WITH A FEDERAL SIGNAL SIREN:

 See Figure 3. 

a.

  If you are installing the system in a vehicle with a Federal Signal 

Convergence Network siren, plug the Convergence Network connector from 

the Message Board into one of the available modular connectors in the back 

of the siren

b.

  Carefully route the included 25-foot CAT5 cable from another open 

connection on the siren through the vehicle to where the control head will 

be mounted. 

c.

  Using the additional modular connector on the back of the Message Board 

control head, plug in any additional Convergence Network control heads.

Figure 3  Convergence Network connections with siren

LED MESSAGE BOARD

25 ft CAT5

290A7199B

SMARTSIREN

CONTROLLER

LED MESSAGE BOARD

CONTROL HEAD

SMARTSIREN

CONTROLLER

OR

PA300-CN

CAT5

CAT5

3. 

Route and connect the 22 AWG black lead to the ground (–NEG) terminal of the 

vehicle battery.

4. 

Route and connect the 22 AWG red lead through a 5 A fuse at the source to the 

positive (+BAT) terminal.

5. 

Route and connect the 22 AWG yellow lead to an appropriate circuit in the vehicle 

that pr12 V when ignition is activated.

6. 

OPTIONAL: For default message activation (message number one), route and connect 

the 22 AWG brown lead through an installer-supplied switch with a capacity of 100 

mA to an appropriate circuit in the vehicle that provides battery ground (-NEG) when 

default message activation is required.

Summary of Contents for MB1

Page 1: ...25500112 REV A1 0920 Printed in U S A Copyright 2015 2020 Federal Signal Corporation Model MB1 LED Message Board Installation Maintenance and Service Manual...

Page 2: ...imited warranty is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness for a particular purpose...

Page 3: ...rols 13 Testing the Message Board System 13 Setting Configuration Options 14 Entering the Standard Menu 15 Entering the Security Menu 15 Exiting the Standard or Security Menu 15 Fleet Password and Sec...

Page 4: ...f the lighting system and may damage the components Verify or test your combination to ensure that the system works together and meets federal state and local standards or guidelines Electrical Hazard...

Page 5: ...echanical damage to the vehicle Refer to the manual packed with the lighting system for proper electrical connections additional precautions and information Locate the light system controls so the VEH...

Page 6: ...onvergence Network products For programming and operating instructions refer to Federal Signal doc no 25500056 The Message Board housing is coextruded polycarbonate with polycarbonate end caps and ela...

Page 7: ...ge 1 4 20 SS 70100531 12 2 Bolt Carriage 3 8 16 SS 7004A024 16 4 Nut Keps 1 4 20 SS 7058050 2 Nut 3 8 16 Hi Corr Resistant 7059124 4 Washer Flat 1 4 inch SS 7072A024 2 Washer Flat 3 8 inch SS 7072A035...

Page 8: ...e drilling All drilled holes should be deburred and all sharp edges should be smoothed All wire routings going through drilled holes should be protected by a grommet or convolute split loom tubing 6 D...

Page 9: ...all auxiliary devices on the light bar or the warning system may fail LOCATING OPERATOR CONTROLS The controls for the light system must be located so that the VEHICLE and CONTROLS can be operated safe...

Page 10: ...wires from the control head must be wired directly to battery power and not to a switched power source Failure to do so may reduce the lifetime of its internal battery required to keep accurate time T...

Page 11: ...n any additional Convergence Network control heads Figure 3 Convergence Network connections with siren LED MESSAGE BOARD 25 ft CAT5 290A7199B SMARTSIREN CONTROLLER LED MESSAGE BOARD CONTROL HEAD SMART...

Page 12: ...t that you fully understand how to safely operate this warning system before use Operate your vehicle and its light sound system in accordance with your department s Standard Operating Procedures If a...

Page 13: ...esight when viewed at close range Do not stare directly into the lights at close range or permanent damage to your eyesight may occur To test the Message Board system 1 Follow all the instructions in...

Page 14: ...ller during installation of the Message Creation software For more information see Fleet Password and Security on page 15 To navigate menus use the up down arrows or simply press the number associated...

Page 15: ...t Password created by the installer during installation of the Message Creation software You have three attempts to enter the Fleet Password correctly The fourth attempt locks the menu Battery power m...

Page 16: ...avigate to the Security Menu see page 14 and use the Reset Fleet Password menu option If you do not know the Fleet Password To unlock the control head 1 Disconnect and apply 12 V BAT on the yellow blu...

Page 17: ...shoe shaped wire in it to see if it has burned through and broken the circuit Figure 4 Fuse location on PCB DRIVER SIDE END CAPS PHILLIPS PLASTITE SCREW 4 ALUMINUM CARRIER 15 A BLADE FUSE ON PCB 290A7...

Page 18: ...ignal factory provides technical assistance with any problems that cannot be handled locally Any units returned to Federal Signal for service inspection or repair must be accompanied by a Return Mater...

Page 19: ...ual Federal Signal www fedsig com Ordering Replacement Parts Ordering Replacement Parts To order replacement parts please contact your local dealer distributor or Customer Support Federal Signal Corpo...

Page 20: ...l Signal Drive University Park Illinois 60484 3167 www fedsig com Customer Support Police Fire EMS 800 264 3578 1 708 534 3400 Work Truck 800 824 0254 1 708 534 3400 Technical Support 800 433 9132 1 7...

Reviews: