Overview
11
Installation and Maintenance Instructions
Federal Signal
www.fedsig.com
Programmable Input Circuits
Pathway has connections for four general-purpose input circuits, plus dedicated
inputs for park, horn and igniton. The inputs are most commonly used for switches
that send a signal to the siren when a condition in the vehicle changes.
LED Indicators and Visual Diagnostics
All buttons on the control head glow when the system is on. Pressed buttons
turn bright to indicate that the function they control is active. The buttons are
programmable for red or blue backlighting. LEDs on the keypad mimic these active
SignalMaster patterns: Left, Right, Center-Out, and Warn. An LED glows over the
position in which the slide switch is placed. Diagnostic LEDs for speaker fault
detection are also available and are programmable.
System Specifications
Table 1
System Specifications
Input Voltage
11 Vdc to 28 Vdc
Polarity
Negative ground only
Operating Temperature Range -40°C to +80°C (-40°C to +176°C) (all relays at 50% power)
Standby Current
Less than 0.1 A
Max Input Current
56 A (siren and relays)
Dimensions:
Height
2.5 in (6.4 cm)
Width
6.0 in (15.2 cm)
Length
8.4 in (21.3 cm)
Net Weight
3.9 lb (1.77 kg)
Siren Specifications
Table 2
Siren Specifications
Speakers
One 100 W, 11-ohm speakers
Operating Current
100 W - One 11-ohm speaker – 8 A
(13.6 V battery, No Relays active)
Frequency Range
182 to 1600 Hz
Nominal Cycle Rate
Wail: 12 cycles per minute
Yelp: 180 cycles per minute
Priority: 370 cycles per minute
High-Low: 60 cycles per minute
Nominal Voltage Output
64 V peak-to-peak (siren tones)
Audio Response
300 Hz to 3,000 Hz ± 3 dB
Siren Tone Compliances
SAE J1849 JUL89