58
Options
UltraVoice (UV)
Model HTR4 (Battery Warmers)
Battery Warmers require 120 Vac.
In locations where temperatures may drop below freezing for extended periods, the
optional battery warmers are recommended to maintain battery efficiency. A thermostat
provides on/off control of the warmers that senses the inside temperature of the Battery
Cabinet. The battery warmer option is equipped with four battery warmers that are
wrapped around each of the four batteries in the Battery Cabinet. The warmers are
plugged into the cube taps, which plug into the thermostat cube, which is plugged into
a 120 Vac outlet that is provided for in the Battery Cabinet. No other connection or
mounting is required for this option.
Figure 19 HTR4 Wiring Diagram
4 BATTERY SYSTEM SHOWN
HTR4 WIRING DIA.
291A102D
POWER
SUPPLY
8287A638A-01
AC THERMO CUBE
288641A
BATTERY
WARMERS
BATTERY
CABINET
Electrocution or severe personal injury can occur when making electrical
connections, drilling holes, or lifting equipment. Therefore, only experienced
electricians should install this product in accordance with national and local
electrical codes.
Solar Power (PVS220W-24)
The solar option allows the siren to operate in areas where power is not available. The
PVS2110-24 model for the UV controller include a solar regulator and solar panel kit.
When installed, the batteries are charged by the battery charger through the photovoltaic
charging system, instead of a battery charger, to provide operational power to the siren.
Summary of Contents for ultravoice UV
Page 42: ...42 Installation UltraVoice UV Figure 15 Omni Antenna Installation Example...
Page 43: ...43 Installation Installation Operation and Service Manual Figure 16 Antenna Grounding...
Page 71: ...71 Appendix C Drawings Figure 25 UV Controller Two way Radio Wiring Diagram...
Page 72: ...72 Figure 26 UVTD IP Broadband Wiring Diagram...