- 9 -
IMPORTANT: When placing cases in a line up the number of end panels used will be different. The cut
out and hole placement dimension will need to be adjusted for each particular line up circumstance. See
LINE UP INTALLATION section of this manual.
CENTER DIVIDER,
MUST BE SEALED
(GASKET PROVIDED)
14.25 /
15.50 SS
26.9
32.8 (36)
44.8 (48)
GASKET
DISCHARGE GRILL
(PROVIDED)
LOCATED AS SHOWN
95 SQ. IN. MINIMUM
OF AIR OPENING
INTAKE GRILL(PROVIDED)
LOCATED AS SHOWN
95 SQ.IN. MINIMUM OF AIR OPENING
SEAL
WITH
GASKET
BASE OF UNIT MUST SIT INTO
OPENING AS SHOWN.
GRILLS CAN BE INSTALLED ON EITHER FRONT
OR BACK OF CABINET. (FRONT SHOWN)
CONDENSER HOUSING,
DO NOT MOUNTGRILL BEHIND
CONDENSER HOUSING
1/2"
O
HOLE
TO FASTEN CASE
TO COUNTER WITH
1/4" X 2" SCREWS
PROVIDED
33.5 (36)
45.5 (48)
TYPICAL COUNTER CUT OUT
A
A
SECTION AA
1.5
CORD OPTION 1: The electrical cord is shipped from the factory protruding from the bottom rear corner
of the base and will fall through the required cut in counter. After the case has been installed and fastened
onto the counter, plug cord into a proper power source.
CORD OPTION 2: An additional electrical cord connection hole is provided in the rear control panel
next to the case’s controls. A 1-1/2”dia hole through the counter is not required for this option. NOTE:
Only a licensed electrician must perform the electrical work required to move the cord to this optional
position.
DANGER:
Electric shock hazard. Do not operate unit with panels removed.
1.
Remove the (8) screws holding the rear frame panel located under the door track and also remove
the 7/8” hole plug located next to the controls in the control panel.
2. Disconnect the power cord connections and move the cord and cord strain relief from the bottom
hole in the frame channel to the hole in the control panel and reconnect power cord. Plug bottom
hole in frame channel with the 7/8” hole plug removed from the control.
3. Reinstall the rear frame panel.
Refrigerated CRR Remote Models: