IMSS E3265
- 68 -
Remote IMSS120R AFTER 12/1/19
California Residents Only.
WARNING
This product can expose you to chemicals including chromium which is known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information
go to
www.P65Warnings.ca.gov
R
COLOR CODE
B = BLUE
Y = YELLOW
W = WHITE
R = RED
BLK = BLACK
BRW= BROWN
R
CONDENSATE PUMP
OR EVAPORATOR
BLK
BL
K
G
DARK LINES REPRESENT
(3) CONDUCTOR CORD
POWER
R
SWITCH
BLK
R
Y/G
G = GREEN
L1
L2 N
LIGHT SWITCH
R
BL
K
Y
R
BL
K
Y
BL
K
BL
K
REFRIGERATION
SOENOID
BLK
CAP EXTRA
BLACK WIRE
IF NOT USED
BL
K
BLK
EVAP.
FANS
BLK/RIB
BLK/RIB
BLK
BLK
BLK
M
PLUG
M
BLK
BLK/RIB
BLK
M
BLK
BLK/RIB
BLK
BLK
BLK/RIB
BLK
BLK
EVAP.
FANS
BLK/RIB
BLK/RIB
BLK
BLK
BLK
M
PLUG
M
BLK
BLK/RIB
BLK
M
BLK
BLK/RIB
BLK
BLK
BLK/RIB
BLK
B
BRW
RIB
BASE FAN OPTIONAL
B
W
W
B
8 9 10 11
5 4 6 7
DEFROST PROBE PB2
TEMP PROBE PB1
W
B
G
B/BL
BL -
R +
G
BL
K
R
LIGHT CIRCUIT
TYPICAL (2)
- B
+B(RIB)
SHELF LAMP
- B
+B(RIB)
SHELF LAMP
- B
+B(RIB)
SHELF LAMP
- B
+B(RIB)
TOP LAMP
- B
+B(RIB)
SHELF LAMP
- B
+B(RIB)
SHELF LAMP
- B
+B(RIB)
SHELF LAMP
- B
+B(RIB)
TOP LAMP
IMSS120 REMOTE ITC LED 91-19740-2 1/17/20
B/R
IF LIGHT WIRES
ARE B/BL & B
TIE B/BL TO RED
& B TO BLUE ON
POWER SUPPLY
B/BL
B/BL
B/BL
B/BL
B/BL
B/BL
B/BL
B/BL
B/BL
B/BL
B/R
B/R
B/R
B/R
B/R
B/R
B/R
B/R
B/BL
B/BL
B/BL
B/R
B/R
B/R
B/BL
B/BL
B/BL
B/R
B/R
B/R
RIBBON
CABLE
TEMP 1 TEMP 2
Red
TEMP 3
Blk Grn
Sh B
A
RSV-Blue
Empty
Org
Red
Yel
Grn
Red
Wht
Blk
Blk
TEMP & VALVE
CONTROL
PRESS. TRANS.
TEMP SENSOR
1
2
3
4
5
EEV
R
BLK
FAN
4 5
RELAY
M
REMOTE
COMPRESSOR
HI/LO PRESS SW
Y
Y
OPTIONAL REMOTE
MOUNTED & WIRED
COMPONENTS
ALL FIELD WIRED
SEPARATE
POWER SUPPLY
PRESSURE
CONTROL
REMOTE