IMSS E3265
- 12 -
Condensate Evaporator (Standard 3 Shelf Self Contained Models)
NOTICE:
During normal defrost cycles, steam from the condensate
evaporator may be visible around the case.
The standard Self-Contained case is furnished with an electric condensate evaporator.
Plumbing connections are not required.
The condensate evaporator can be removed from the case and the condensate drain
can be plumbed to a drain to conserve energy if desired. Disconnect the condensate
evaporator wires at the condensate evaporator to remove. This must be done by a
qualified electrician.
This is an open merchandiser and at times can produce a large amount of condensate
water. To ensure that adequate evaporator capacity is available, a high wattage heater
is used. The heater turns off automatically when the water level in the pan drops.
Make sure that the drain line has not been dislodged during shipment and that the drain
trap terminates properly over the water reservoir.
Condensate Pump (Standard - Remote & 2 Shelf Self-Contained,
Optional
– 3 Shelf Self Contained)
NOTICE:
This unit could be shipped with an optional condensate pump. The pump has a
float that turns the pump on automatically when needed.
The pump is mounted in the base compartment. The pump should be cleaned and
inspected every 3-4 months.