Page 10 of 40
5.5
REFRIGERATION SYSTEM
5.5.1
Self Contained Models
The self-contained models are shipped from the factory with a completely operational 404A
refrigeration system and require no modifications or adjustments upon installation. Case must be
installed as per the installation section of this manual to provide proper condensing air cooling.
5.5.2
Remote Models
The remote models are designed to use 404A refrigerant and shipped from the factory with the
evaporator coil, expansion valve, sight glass, service valves and refrigerant solenoid valve. Installation
must be performed by a licensed Refrigeration Technician. See the Service section of this manual for
installation requirements.
5.6
EVAPORATOR CONDENSATE DRAIN TUBE
WARNING TO INSTALLER:
Evaporator Condensate Drain Tube may become dislodged during shipping. Installer must
check Evaporator Condensate Drain Tube upon installation to be sure drain tube is properly
seated and installed correctly.
Evaporator Drain Tube must be attached to tube protruding from bottom of Evaporator Tub and must either
be inside the Condensate Pan area or inside of hole of Condensate Pump.