Removing Case From Shipping Skid
CAUTION: If a Johnson bar or pry bar is used to move the case, make certain that
the case is lifted under the welded steel frame, and not by the end panels of the case.
Damage to the ends will result from lifting under the end panels.
Move the case as near as possible to the final location before removing it from the
shipping skid. Having removed the front and rear compressor compartment grills. Remove
the (three or four sets of bolts, nuts, and washers depending on case size) that secure the case to the
shipping skid. Discard these bolts, nuts, and washers.
Removing Packaging Material
Remove bubble wrap and packing material for all shelves, etc. If it is
necessary to remove tape residue from various materials, use cleaning
compounds recommended in the cleaning section of this manual.
Leveling the Case
The case must be level for proper drainage of defrost water to the condensate evaporator or
condensate pump.
Check the level of the case along the front rail and along the top of the display pan. Shim
under the case frame as needed to level the case or if case is equipped with leg levelers,
adjust them up or down to level the case. It is recommended that the leveled case be sealed to
the floor with an NSF Listed Sealant.
Condensate Evaporator
NOTICE: Steam from the condensate evaporator may be visible around the
base of the merchandiser during normal operation.
This merchandiser may be furnished with an electric condensate evaporator, or a
electric condensate pump. Plumbing connections are not required, unless
merchandiser is specifically ordered without a condensate evaporator or pump.
The condensate evaporator can be removed from the merchandiser and the
condensate drain can be plumbed to an external drain to conserve energy. To remove
the condensate evaporator disconnect the wires at the condensate evaporator. This
must be done by a qualified electrician.
This is an open merchandiser and can produce a large amount of condensate water.
To ensure that adequate evaporator capacity is available, a high wattage heater is
used.
Make sure that the condensate drain line has not been dislodged during shipment and
that the drain trap terminates properly over the water reservoir.