Removing Packaging Material
Remove the brackets that held the case to the shipping skid.
Remove the shipping tape that secures the doors and lift-up glass. If it is necessary to
remove tape residue from plastic materials, use cleaning compounds recommended in
the cleaning section of this manual.
Leveling the Case
The case must be level for proper drainage of defrost condensate to the condensate
evaporator.
Four (4) leg levelers are provided for leveling the case. The leg levelers can be turned
in, and the case can be placed with the base frame on the floor.
The leveled case can be sealed to the floor using and NSF Listed Sealant.
Grill Removal
The front of the case has a removable base panel to access the refrigeration
components. Normally, it is not necessary to remove the panel to install the case. This
panel must be in place for proper operation of the case.
There is one (1) removable panel on the back of the case. The panel allows access to
the condensing unit, and the field wiring connection box. Remove this panel to make
field-wiring connections.
Condensate Evaporator
This case is furnished with an electric condensate evaporator. Plumbing
connections are not required.
The condensate evaporator is located behind the rear panel and is accessible from
the rear of the case.
Make sure that the drain line has not been dislodged during shipment and that the
drain terminates properly over the water reservoir.
Lights
The ballasts used on this case allow removal of one or more top lights without
affecting the remaining lights.
Market Deli Refrigerated Cases
Page 4
DANGER: Electrical shock hazard. Do not operate unit with
panels removed.