background image

18

H O M E O W N E R   S E C T I O N

AromaSteam 

Operation and Installation Instructions 

®

• Keep away from heat, sparks, open flames, & hot surfaces 
• No smoking 
• Keep container tightly closed 
• Ground/bond container and receiving equipment 
• Use only non-sparking tools 
• Take precautionary measures against static discharge 
• Use explosion-proof equipment 
• Wear protective gloves, protective clothing, eye 

protection or face protection 

• Store in a well-ventilated place 
• Keep cool 
• Dispose of contents and container at an approved 

waste disposal plant 

• To prevent spillage always use with the caddy provided 

with the pump 

• Keep away from children

First Aid 

 

In case of Eye Contact 

Rinse immediately with plenty of water, also under the 

eyelids, for at least 15 minutes. If eye irritation persists: 

Get medical advice/attention. 

In case of Skin Contact

 

Remove/Take off immediately all contaminated clothing. Rinse 

skin with water/shower. If skin irritation persists, call a physician. 

In case of Inhalation

 

Remove exposed individual(s) to fresh air for 20 minutes. 
Consult a physician/poison center if individual's condition 
declines or if symptoms persist. 

In case of Ingestion

 

Rinse mouth thoroughly with water. Do NOT induce 
vomiting. If conscious give large amounts of water. If 
symptoms persist, call a physician.

Important Notes:

 

 

• Not for use in acrylic or fiberglass rooms. Check with the room manufacturer to determine compatibility of these 

fragrances with room construction materials. 

• Do Not alter or modify any MrSteam product. Doing so will void the warranty. 

• MrSteam Aroma fragrances must be disposed of as hazardous waste.

• Avoid fragrance contact with eyes. May cause mild eye 

irritation. Ingestion may cause irritation, nausea, 

vomiting. 

• Fragrance vapors may cause drowsiness, allergic 

reactions, difficulty breathing or skin irritation. If 

condition persists get medical attention. 

• The Fragrance Safety Data Sheet provides 

comprehensive information about MrSteam Aroma 

fragrances. Contact 1-800-767-8326 or go online at 

www.mrsteam. com for a copy of the Safety Data Sheet. 

• MrSteam fragrances (MS OIL 1-5) are only for use with 

the MrSteam AromaSteam (part number MS AROMA 

and MS AROMAC). Never use MrSteam fragrances in 

any other AromaSteam, spray or dispens ing device. 

The use of MrSteam fragrances in any other device may 

cause personal injury. 

• The use of any fragrances other than MrSteam 

fragrances with a MrSteam AromaSteam may introduce 

excessive concentration of fragrances into the steam 

room, resulting in personal injury. 

• Keep out of the reach of children. 

• The AromaSteam has been factory set to deliver a 

suitable amount of fragrance into a typical sized 

residential or Day Spa steam room. Start with the 

AromaSteam volume at a very low setting. Gradually 

increase the volume setting until a comfortable 

fragrance level is reached. Do not exceed the 

“Recommended Setting” indicated on the 

AromaSteam volume. 

• Do Not alter or modify any MrSteam product. Doing so 

may result in a personal injury.

FLAMMABLE LIQUID AND VAPOR 

IMPORTANT SAFETY INSTRUCTIONS  

READ AND FOLLOW ALL INSTRUCTIONS 

Summary of Contents for mr. steam AromaSteam MS AROMA

Page 1: ...e Manual Steambath Generator Systems Residential Models MX4E 6E mr steam l Feel Good Inc Installation Operation Maintenance Manual AromaSteam Fragrance Metering Pump for Residential and Day Spa Steam Rooms Part Number MS AROMA 104496 __________________________________ IMPORTANT Leave this material with the home owner __________________________________ ...

Page 2: ...r installation leave this document with the homeowner Do not discard this document The information in this manual should be used in conjunction with consultations with an architect designer and contractor in determining factors necessary in providing a suitable and safe steam room The MrSteam AromaSteam is intended to be operated with MrSteam iSteam AirTempo or iTempoPlus controls only The control...

Page 3: ...System for Residential and Day Spa Steam Rooms Part Number MS AROMA 120V This installation operation and maintenance manual is for general reference The installation operation and maintenance manual supplied with the product must be used for installation operation and maintenance purposes Failure to use the installation operation and maintenance manual supplied may result in a property damage or p...

Page 4: ...e into a typical sized residential or Day Spa steam room Start with the AromaSteam volume at a very low setting Gradually increase the volume setting until a comfortable fragrance level is reached Do not exceed the Recommended Setting indicated on the AromaSteam volume Do Not alter or modify any MrSteam product Doing so may result in a personal injury Discontinue use of the steam generator and con...

Page 5: ...monitor the consumption of fragrance and for easy replacement 3 The AromaSteam should not be installed in areas accessible to children A locked room is strongly recommended i e utility room 4 The AromaSteam is designed and intended for indoor use only and is to be located indoors in a dry clean location and not subject to moisture condensation or similar high humidity environments 5 Do not install...

Page 6: ...awings for Illustrative Purposes Only AromaSteam Overview AromaSteam Pump AromaSteam Transformer 120VAC 240VAC Typical MrSteam Steam Generator shown with cover removed Steam Generator Printed Circuit Board Request Cable Pressure Hose Steam Head Steam Line 90 T Check Valve Receptacle required ...

Page 7: ...ck Valve Pressure Hose 6ft Steam Generator Steam Pipe 90 T Suction Hose AromaSteam Transformer 120VAC 240VAC 4 1 2 ft To Outlet Request Cable 6ft To Steam Generator AromaSteam Pump 5 10ft Optimal Fragrance Container AromaSteam Pump Specs Dimensions 4 3 W x 14 8 H x 5 4 D Weight 5 pounds Supply Voltage 120VAC 240VAC 50 60 Hz Max Current Draw 0 1 Amps General System Dimensions AROMASTEAM ...

Page 8: ...a where the ambient temperature does not exceed 88o F 8 I N S T A L L E R S E C T I O N AromaSteam Operation and Installation Instructions All Drawings for Illustrative Purposes Only Tools required Cordless drill with a Phillips bit Level Use only non sparking tools Take precautionary measures against static discharge Mounting the AromaSteam on a Wall 1 Pre drill as required and install the two sc...

Page 9: ... Operation and Installation Instructions All Drawings for Illustrative Purposes Only Drill Template IMPORTANT NOTE Do no scale template Template must be printed at 1 1 scale WARNING Failure to print template at 1 1 scale will result in wrong mounting hole locations ...

Page 10: ...om to download this document Install Check Valve into 90 T adaptor Failure to install the supplied Check Valve may result in excessive fragrance delivery into the steam room and cause dizziness and or personal injury The supplied Check Valve prevents excessive amounts of fragrance from entering the steam line and steam room Never install the AromaSteam without the supplied Check Valve 10 I N S T A...

Page 11: ...fragrance container are seated in rectangular openings on the bottom of the AromaSteam 4 Insert the fragrance container with its label facing outward so it is visible at all times This label contains important information Bottom Diagram IMPORTANT NOTE To prevent damage do not use tools to tighten the container cap 11 I N S T A L L E R S E C T I O N AromaSteam Operation and Installation Instruction...

Page 12: ...hafing 4 Locate the two quick connect tabs labeled AROMA on the printed circuit board in the location shown 5 Connect the request cable to the terminals The terminals are not polarized 6 Connect AromaSteam s transformer into a 120VAC 240VAC wall outlet I N S T A L L E R S E C T I O N AromaSteam Operation and Installation Instructions AromaSteam Connections Steam Generator Circuit Board AromaSteam ...

Page 13: ...d location of 900 T IMPORTANT NOTE If liquid is not filling tubing in AromaSteam head release priming button and check if suction hose is securely installed onto barb fitting below AromaSteam head and check valve IMPORTANT NOTE If an extended pressure hose is needed please contact MrSteam Technical Service 13 I N S T A L L E R S E C T I O N AromaSteam Operation and Installation Instructions Steam ...

Page 14: ...ped into the steam line at preset intervals Activating the AromaSteam from an iSteamX Control 1 Press the START button to turn the steam generator on 2 In the dashboard press the AromaSteam icon flower on the left then press the On Button to start or Off button to stop 3 Aroma fragrance will automatically be pumped into the steam line at preset intervals Activating the AromaSteam from iTempo Plus ...

Page 15: ...h the Check Valve when the AromaSteam is energized Apply compressed air through the Check Valve Attach the compressed air at the point of connection of the pressure hose 8 Ensure the AromaSteam has been powered up AromaSteam fragrance delivery too much or too little The AromaSteam has been factory set to deliver a suitable amount of aromatic fragrance into a typical sized steam room Please contact...

Page 16: ...04255 AromaSteam Transformer 120VAC 240VAC 104494 Replacement Parts This AromaSteam is factory wired If the power cord of the AromaSteam is damaged it must be replaced by the MrSteam service department or similarly qualified personnel in order to avoid an electric shock hazard All electrical connections to be made by a licensed qualified electrician Disconnect all power to the steam generator befo...

Page 17: ...ose and sinuses The Safety Data Sheet provides comprehensive information about MrSteam Aroma fragrances Contact 1 800 767 8326 or go online at www mrsteam com for a copy of the Safety Data Sheet MrSteam Aroma Fragrances MS OIL 1 5 READ ME FIRST Warning As you follow these instructions you will notice warning and caution symbols This blocked information is important for the safe and efficient insta...

Page 18: ...ith room construction materials Do Not alter or modify any MrSteam product Doing so will void the warranty MrSteam Aroma fragrances must be disposed of as hazardous waste Avoid fragrance contact with eyes May cause mild eye irritation Ingestion may cause irritation nausea vomiting Fragrance vapors may cause drowsiness allergic reactions difficulty breathing or skin irritation If condition persists...

Page 19: ...ture does not exceed 88 o F Using a fragrance container that is not secured in the AromaSteam or using a AromaSteam that is not mounted may result in spillage excessively strong vapors or a fire hazard 6 Insert the fragrance container with the label facing outward so it is visible through the AromaSteam The label contains important information 7 Always keep the container in the AromaSteam while it...

Page 20: ...e steam line at preset intervals AromaSteam Button chroma time temp aroma AromaSteam Button OPERATION cont mr steam Feel Good Inc PUR103938 REV 2 22 2023 Mr Steam and des AirTempo AromaFlo AutoFlush AutoSteam AudioWizard Butler Package ChromaSteam Clean Steam Every Time Club Therapy Digital 1 Express Steam From Bathroom to Spa HomeWizard iButler iTempo iTempo Plus iGenie iSizing iSteam Linear Stea...