background image

FeelElec

 

 

FY8300 Series User

s Manual                                                                                   

37

 

Save and Load 

 

Press 

SAVE

  button  in  System  interface  to  save  parameters  of  current 

waveform  to  specified  position.  Press 

LOAD

  button  to  load  parameters  of 

waveforms previously set to current system status. 

Select 

S xx

 on the right to save current parameters to corresponding position,

 

The parameters stored in storage location 01 will be loaded automatically at the 
next boot. 

Select 

L  xx

 on the right  to load parameters from corresponding position to 

current system status. 

  FY8300 provides 12 positions for saving. 

  The  generator  will  load  default  parameters  from  Position  01 

automatically after start-up.   

  In  the  waveform  parameter  setting  interface,  press  OK  button  for  1 

second.  The  system  saves  the  current  waveform  parameter  in  the 
storage location 01. The next time the system starts, the system loads 
automatically. 

Summary of Contents for FY8300 Series

Page 1: ...FeelElec FY8300 Series Fully Numerical Control Three Channel Function Arbitrary Waveform Generator User s Manual Rev1 0 May 2019 ...

Page 2: ......

Page 3: ...ly corresponding material FeelElec shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information contained Any part of this document is forbidden to be copied or photocopied or rearranged without prior written approval of FeelElec Contact Us If you have any problem or requirement when using...

Page 4: ...utput Channel 17 Select Waveform 18 Set Frequency 20 Set Amplitude 21 Set Offset 22 Set Duty Cycle Rectangle 23 Set Phase 24 Enable Output 25 Example Output Sine Waveform 26 Frequency Meter Counter 28 Enable the Counter 28 Set the Counter 29 Sweep 30 Sweep Object 30 Sweep Start Position 31 Sweep End Position 32 Sweep Time 33 Enable Sweep Function 35 System Configuration and Auxiliary Functions 36 ...

Page 5: ...hortcut keys and graphical user interface simplifies every operation Users do not have to spend a lot of time to learn and familiar with the operation of the instrument you can be skilled use For education research and development production testing maintenance and other industries to provide a new choice The instrument adopt the Direct Digital Synthesizer DDS technology and provide stable precise...

Page 6: ...he three channels can be updated according to user s configuration at the same time when the tracking is opened Can output up to 100 groups of functions arbitrary waveform contains 33 groups of preset waveforms and 64 groups of user defined waveforms Preset waveforms Sine Square Duty Cycle adjustable Pulse Pulse width and cycle time can be set accurately Triangle Ramp CMOS 0 12V Four channels TTL ...

Page 7: ...e function It can save 12 sets user set parameters and can be loaded at any time Communicating function All functions can be controlled by PC program and the communication protocol is open for secondary development Output short circuit protection All channels can work more than 60 seconds when the load is short circuited Provide powerful waveform editing PC software Users can download arbitrary wa...

Page 8: ... shipment have been checked for completeness and the instrument has passed both electrical and mechanical tests The consigner or carrier shall be liable for the damage to instrument resulting from shipment 2 Inspect the instrument In case of any damage or defect or failure notify your FeelElec sales representative 3 Check the accessories Please check the accessories according to the Appendix C pac...

Page 9: ...Press corresponding button to activate submenu represented 3 Function Buttons Area Press this buttons to switch waveforms among Sine Square Rectangle Triangle and so on Can sweep Sine Square Arbitrary and so on Can sweep frequency amplitude offset and phase 2 sweep types Linear Logarithm Press this button to switch between frequency meter and counter to measure frequency period duty cycle and puls...

Page 10: ...r indicator keeps illuminating when power on Press the power button and the indicator change to notifylight status and the signal output terminates 7 CH1 channel output connector CH1 connector output impedance is 50Ω When CH1 channel activates indicator illuminates CH1 outputs signal with parameters set 8 Output Channels Control CH1 output Press it to switch to CH1 parameter setting interface Pres...

Page 11: ...nnector output impedance is 50Ω When CH2 channel activates indicator illuminates CH2 outputs signal with parameters set 10 CH3 channel output connector CH3 connector output impedance is 50Ω When CH3 channel activates indicator illuminates CH3 outputs signal with parameters set ...

Page 12: ...n signal output terminal SYNC IN Synchronization signal input terminal 2 TTL signal output Port A The output frequency duty cycle is the same as CH1 and the phase is the reference phase of the instrument constant 0 Port B The output frequency duty cycle is the same as CH1 and the phase is CH1 C port The output frequency duty cycle is the same as C2 and the phase is CH2 D port The output frequency ...

Page 13: ... s Manual 11 Warning To avoid instrument damage voltage of signal input from EXT IN CANNOT exceed 20Vac dc Voltage of signal input from Trig IN CANNOT exceed DC5V Note To ensure the normal work please use 100 240V AC power supply ...

Page 14: ...ss than 10W Power On Turn on the power switch after the power cord is connected The generator will execute self inspection The LCD will show welcome interface after the inspection is over If the generator cannot work normally please check the Chapter Troubleshooting for solution Set the System Language FY8300 series Function Arbitrary Waveform Generator supports Chinese and English system language...

Page 15: ...nel selected 1 4 User Interface CH1 selected Item Description 1 Current channel selected Display current channel selected for operation 2 Current waveform selected Display the name of current waveform selected For example CH1 Sine means current waveform selected of CH1 is Sine Wave It can be changed by press WAVE button Meanwhile waveform can be changed quickly by rotating ADJ Knob when waveform s...

Page 16: ...litude offset and phase information of the output signals of CH1 CH2 and CH3 channels will be reflected in the waveform display window The waveform amplitude displayed in the window will automatically switch gears according to the actual amplitude of the three channels 10 Duty Cycle Display Duty Cycle value of current channel Press DUTY button to highlight it and use ADJ Knob and Arrows to change ...

Page 17: ...ess the corresponding drop button the menu bar will switch in the duty up down function When the drop display value is highlighted the parameter will be changed by the direction key and knob Note The descent edge parameters are only valid for trapezoidal waves ...

Page 18: ...FeelElec 16 FY8300 Series User s Manual Appearance and Dimensions ...

Page 19: ...nstrument to output various waveforms Select Output Channel CH1 CH2 and CH3buttons are used to change current channel selected At start up CH1 is displayed on the top with yellow color and CH2 is displayed on the bottom with blue color Press CH1 CH2 and CH3to select channel needed When selecting CH2 as output channel CH2 parameters displays on the top for configuration KEY POINT CH1 CH2 and CH3 ca...

Page 20: ...arithm Linear FM AM FM Positive Half Wave Negative Half Wave Positive Half Wave Rectification Negative Half Wave Rectification User defined waveform Press WAVE to change waveform selected Or rotate ADJ Knob under waveform switching status to change waveform The waveform diagram displays on the screen Pressing the knob can change to arbitrary waveform directly when choosing waveform At start up Sin...

Page 21: ...c FY8300 Series User s Manual 19 Note Arbitrary waveforms can be edited and downloaded from PC software provided by FeelElec The relevant software and driver can be downloaded from our website www feelelec com ...

Page 22: ...ncy are different For detailed information please refer to Frequency in Specifications The default frequency is 10kHz Press FREQ button to highlight value of Frequency Then use Arrow buttons and ADJ Knob to set the value Press Arrows button to move the cursor and rotate ADJ Knob to set the value Under setting frequency status press ADJ Knob to change frequency units among MHz KHz Hz mHz μHz ...

Page 23: ...y Points 1 What s the difference of amplitude in Vpp and the corresponding value in Vrms Answer Vpp is the unit for signal peak peak value and Vrms is the unit for signal effective value The default unit is Vpp Note For different waveforms the relation between Vpp and Vrms is different The relation of the two units is as shown in the figure below take sine waveform as an example According to the f...

Page 24: ...on and ADJ Knob to set the value Press Arrows button to move the cursor and rotate ADJ Knob to set the value The offset accuracy is 1mV i e 0 001V When frequency output is lower than 20MHz the offset can be adjusted during 12V 12V When frequency output is higher than 20MHz the offset can be adjusted during 2 5V 2 5V ...

Page 25: ...e setting range of duty cycle is 0 1 99 9 Press ADJ Knob under duty cycle setting status will initial the value to 50 Set pulse wave pulse width Adj Pulse wave Adjustable pulse wave refers to the square wave that can hold the fixed pulse width at any frequency that is the pulse width set by the user does not change with the frequency Pulse width setting method in the adjustable pulse wave is selec...

Page 26: ...solution is 0 1 The default phase value is 0 The start phase displayed on the screen is the default value or the phase previously set Then press PHAS button to highlight phase value Then use Arrows button and ADJ Knob to set the value Press Arrows button to move the cursor and rotate ADJ Knob to set the value ...

Page 27: ...rent channel selected is not CH1 then press CH1 to make CH1 as channel selected and press CH1 again to switch between output ON OFF For CH2 there are two status 1 Generator is in parameter setting status and current channel selected is CH2 then press CH2 to switch between output ON OFF 2 Generator is in other working status or current channel selected is not CH2 then press CH2 to make CH2 as chann...

Page 28: ...ADJ Knob to get 2 FREQ 00 020 000 000 000kHz 4 Set the Amplitude Press AMPL to highlight the amplitude value Press Arrow buttons to move the cursor and rotate the ADJ Knob to get the figures below AMPL 02 500V 5 Set Offset Press OFFS to highlight the offset value Press Arrow buttons to move the cursor and rotate the ADJ Knob to get the figures below OFFS 01 600V 6 Set Phase Press button to page do...

Page 29: ...FeelElec FY8300 Series User s Manual 27 ...

Page 30: ...coupling The result will be displayed on the screen in real time The lowest frequency workable is 0 01 Hz GATE TIME 100S Press COUN button to enter external pulse counter function At this time COUN button is turned into FREQ button Repeat pressing this button to switch between FREQ and COUN 2 1 Frequency Meter Counter Interface When the Frequency Meter Counter is turned on press STOP button to pau...

Page 31: ...ser s Manual 29 Set the Counter Gate Time Press GATE button to select gate time The default is 1S It s better to use 10S or 100S as gate time for low frequency signal Gate Time Frequency Resolution 1S 1Hz 10S 0 1Hz 100S 0 01Hz ...

Page 32: ...bjects include frequency amplitude offset duty cycle It can be selected by pressing OBJE button In Frequency Sweep Mode the generator will output signal variably from start frequency to end frequency within the specified sweep time In Amplitude Sweep Mode the generator will output signal variably from start amplitude to end amplitude within the specified sweep time In Offset Sweep Mode the generat...

Page 33: ... 000 000 000kHz Amplitude Sweep Press STAR button to highlight start amplitude parameter Press the Arrow buttons and rotate the ADJ Knob to set the specified value For example START 10 00V Offset Sweep Press STAR button to highlight start offset parameter Press the Arrow buttons and rotate the ADJ Knob to set the specified value For example START 00 00V Duty Cycle Sweep Press STAR button to highli...

Page 34: ...020 000 000 000kHz Amplitude Sweep Press END button to highlight end amplitude parameter Press the Arrow buttons and rotate the ADJ Knob to set the specified value For example END 20 00V Offset Sweep Press END button to highlight end offset parameter Press the Arrow buttons and rotate the ADJ Knob to set the specified value For example END 10 00V Duty Cycle Sweep Press END button to highlight end ...

Page 35: ...nabled press SOUR button to select it and press it again to change between TIME and external sweep VCO Sweep Press the Arrow buttons and rotate the ADJ Knob to set the specified value of weep time The default is 10S The work range is 10mS 999 99S For Example SOUR TIME 999 99S ...

Page 36: ... End value Start value Sweep time 100 Logarithm Sweep In linear sweep type the signal parameter varies logarithmically For example in the frequency sweep the output frequency changes in the way of octave per second or decade per second The variation is controlled by Start Frequency End Frequency and Sweep Time When Logarithm Sweep is enabled users can set the following parameters Start Frequency F...

Page 37: ...the generator sweeps from low frequency to high frequency Start Frequency End Frequency the generator sweeps from high frequency to low frequency Start Frequency Stop Frequency the generator outputs with a fixed frequency When Sweep function is enabled press STAR button to highlight start value Use arrow buttons and ADJ Knob to set the specified value Different frequency sweep corresponds to diffe...

Page 38: ...h the corresponding parameters of channel 1 CONF To set system language turn on off Buzzer and Uplink mode MORE To set default output status of three channels CH1 BOOT ON The default CH1 channel is on to turn on the output state can press the F1 button to set the default output status of the CH1 channel CH2 BOOT ON The default CH2 channel is on to turn on the output state can press the F2 button t...

Page 39: ...e parameters stored in storage location 01 will be loaded automatically at the next boot Select L xx on the right to load parameters from corresponding position to current system status FY8300 provides 12 positions for saving The generator will load default parameters from Position 01 automatically after start up In the waveform parameter setting interface press OK button for 1 second The system s...

Page 40: ... button to turn on off buzzer On is the default Press PHAS button The phase of the three output waveforms can be set in manual automatic state When the waveform parameters are adjusted the phase of the three output waveforms is asynchronous until the user enters the interface of adjusting the phase When the automatic state is activated the phase of the three output waveforms keeps synchronous Pres...

Page 41: ...to set the UPLINK to be ON Set all other machines to be slave machines Press SYS CONF M S to set the UPLINK MODE to be Slave Press UPLI to set the UPLINK to be ON Repeat this step to set all slave machines Connect all FY8300 in parallel by SYNC connecter The uplink machines cannot exceed 8 because the driving ability When the setting above has been finished all machines in network will work synchr...

Page 42: ...ording to variation of CH1 When AMPL is highlighted the amplitude of CH2 CH3 will vary according to variation of CH1 When OFFS is highlighted the offset of CH2 CH3 will vary according to variation of CH1 When CH is highlighted the output state of CH2 CH3 will vary according to variation of CH1 When DUTY is highlighted the duty cycle of CH2 CH3 will vary according to variation of CH1 When RISE is h...

Page 43: ...rument after finishing the above inspections 4 If it still does not work correctly please contact FeelElec CH2 CH3 is locked 1 Check that the signal generator is operating in synchronous state Press the SYNC button to enter the synchronization settings interface to cancel all synchronization parameters 2 If the problem is still please restart the generator Set correctly but no waveform output 1 Ch...

Page 44: ...n Resolution on all frequency range 1μHz Min resolution can reach 1μHz on all frequency range to ensure adjusting accuracy under high frequency For example it can output 10 000000000001MHz signal Accuracy 20ppm Stability 1ppm 3hours Waveform Characteristics Waveforms Sine Square Rectangle Duty Cycle adjustable Pulse Pulse width and cycle time can be set accurately Triangle Ramp Sawtooth Wave CMOS ...

Page 45: ...eform Output Impedance 50Ω 10 Typical Protection All channels can work more than 60 seconds when the load is short circuited DC Offset Offset Range Frequency 20MHz 12V Frequency 20MHz 2 5V Offset Resolution 1mV Phase Feature Phase range 0 359 99 Phase resolution 0 01 TTL Output TTL Level Amplitude 3Vpp Fan out 8 TTL LOAD Rise Fall Time 10ns CMOS Output Low Electric Level 0 3V High Electric Level 1...

Page 46: ...p Setting range Starting position and Finishing position can be set arbitrarily Sweep Range Decided by Parameters setting General Specifications Display Type 2 4 inch TFT Color Display Save Load Amount 12 Position 01 to 12 01 for start default value Interface Type USB to Serial interface Protocol Command line mode providing communication protocols Communicating Speed 115200bps Industrial standard ...

Page 47: ...r death and all the company managers and employees and auxiliary agents distributors other personnel concerned will be released from any claim including all the costs expenses attorney fees etc that may result in Appendix C Accessories and Options Description Quantity Model FY8300 Series DDS Signal Generator 1 Standard Accessories Power Cable 1 USB Data Cable 1 BNC Clip Cable 3 BNC BNC Cable 1 War...

Reviews: