SGP3000 DDS Signal Generator

FeelTech

SGP3000 Series Users Manual

9

Amplitude

10mVpp~20Vpp

Amplitude Resolution 1mV(Attenuate 20dB)
Amplitude Stability

±0.5%/ 5

小时

Amplitude flatness

±5%(<10MHz)

±10%(>10MHz);

Waveform Output

Impedance

50Ω±10%

Typical

Protection

All terminals can work more than 60 seconds when the load is
short-circuited.

Dc Offset

Offset Range

±10V

Offset Resolution

0.01V (0.001V Attenuated)

TTL output

Electrical

Level

Amplitude

>5Vpp

Fan-out

>20 TTL Load

Rise/Fall Time

≤20ns

CMOS output

Low Electric Level

<0.3V

High Electric Level

1V~10V

Rise/Fall Time

≤20ns

External Measurement

Frequency Meter

Range

1Hz~60MHz

Sensitivity

Gate Time 1S

Counter

Range

0-4294967295

Coupling

AC

Working Mode

Manual

Voltage Input Range

0.7Vpp~20Vpp

Sweep

Sweep Type

Linear, Logarithm

Sweep Objects

Frequency

Sweep Time

1S~999S/

Step

Sweep Range

Starting position and Finishing position can be set arbitrarily.

General Specifications

Display

Mode

LCD1602

Summary of Contents for FY2300 series

Page 1: ...FeelTech FY2300 Series Fully Numerical Control DDS Signal Generator User s Manual Rev2 0 Feb 2016...

Page 2: ......

Page 3: ...n in this publication replaces all previously corresponding material FeelTech shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or perfo...

Page 4: ......

Page 5: ...interference immunity and operational life span The advantages of this instrument in signal generating waveform sweeping parameter measurement and other fields make it to be the ideal equipment for e...

Page 6: ...n can output any CMOS electric level with amplitude during 0 10V Save Function It can save 30 sets of user defined parameters and can be loaded at anytime It has built in 60MHz frequency meter and cou...

Page 7: ...the cursor twinkles under the frequency value If not please keep pressing MENU button to move the cursor to the first line Use button to change the value of frequency for increasing for decreasing F...

Page 8: ...to change the value F 00021 00000kHz AMPL 05 00V TRGL 4 To set the offset Press OFFS button to make the cursor stay under the offset value OFS Then use to change the offset value F 00021 00000kHz OFS...

Page 9: ...witch between frequency meter and counter 1 Frequency measurement mode ExtF 21 000kHz FUNC EXT TREQ Measure FREQ 2 Pulse counter mode CNTR 0 FUNC COUNGTER Measure COUNT Press OK button canreset the co...

Page 10: ...10 ms The step value is calculated by the instrument itself 9 Load Save function Press SYS button to enter Save Load function This function allow the user to save to or load from M0 M30 for frequency...

Page 11: ...w Press Output again to turn on the output F 00021 00000kHz AMPL 05 00V OFF Other Functions 1 Dual Channel TTL output 2 Buzzer It beeps each time press a button The beep will last a while if operation...

Page 12: ...5MHz Ramp Triangle 0 2MHz 0 5MHz 0 5MHz 0 5MHz Pulse 0 2MHz 0 5MHz 0 5MHz 0 5MHz TTL 0 2MHz 0 5MHz 0 5MHz 0 5MHz Others 0 2MHz 0 5MHz 0 5MHz 0 5MHz Resolution 10mHz 0 01Hz Accuracy 5 10 6 Stability 1...

Page 13: ...n 0 01V 0 001V Attenuated TTL output Electrical Level Amplitude 5Vpp Fan out 20 TTL Load Rise Fall Time 20ns CMOS output Low Electric Level 0 3V High Electric Level 1V 10V Rise Fall Time 20ns External...

Page 14: ...erial interface Communicati ng Speed 9600bps Protocol Command line mode protocol complete open Power Voltage Range DC12V Buzzer Can be turned on off by setting Operation Button controlled Environment...

Page 15: ...pecial purpose or use authorization Before the installation and use each parameter of the technical indexes in this manual should be referred to If this suggestion is not obeyed death or serious perso...

Page 16: ...duct is proven to be defective within the respective period FeelTech guarantees the free replacement or repair of products which are approved defective This product enjoy 1 year warranty since its del...

Reviews: