SGP3000 Series Users Manual

High frequency resolution: full range of 10 mHz frequency resolution

High amplitude resolution: minimum resolution can be 10 mV.

No range limit: full frequency range without stage, direct digital Settings

Frequency sweep function: It has Linear and Logarithm two sweep types.

Sweep time can be up to 999.99S. Sweep starting point and end point can be set
arbitrarily.

It has pulse train burst output function. There has Manual Trigger and

External Trigger two modes. It can output 1~65536 pulse trains.

It has -10V~+10V DC offset function. The resolution can be 0.01V

It has digital signal output function can output any CMOS electric level

with amplitude during 0~10V

Save Function

It can save 30 sets of user defined parameters and can be

loaded at anytime.

It has built-in 60MHz frequency meter and counter.

All parameter can be adjusted by internal program.

Powerful communication function. The instrument can be controlled by

other equipment through TTL serial port. Communication protocol is open for
secondary development.

High reliability: large scale integrated circuit and SMT technology, high

reliability, long service life.

Output short-circuit protection: All terminals can work more than 60

seconds when the load is short-circuited.

Can choose our FYV2000 series or FPA1000 series power amplifier to

output 20W or higher signals in DC-2MHz width without any distortion. The
highest power can be up to 60W with our FPA1016 amplifier.

Summary of Contents for FY2300 series

Page 1: ...FeelTech FY2300 Series Fully Numerical Control DDS Signal Generator User s Manual Rev2 0 Feb 2016...

Page 2: ......

Page 3: ...n in this publication replaces all previously corresponding material FeelTech shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or perfo...

Page 4: ......

Page 5: ...interference immunity and operational life span The advantages of this instrument in signal generating waveform sweeping parameter measurement and other fields make it to be the ideal equipment for e...

Page 6: ...n can output any CMOS electric level with amplitude during 0 10V Save Function It can save 30 sets of user defined parameters and can be loaded at anytime It has built in 60MHz frequency meter and cou...

Page 7: ...the cursor twinkles under the frequency value If not please keep pressing MENU button to move the cursor to the first line Use button to change the value of frequency for increasing for decreasing F...

Page 8: ...to change the value F 00021 00000kHz AMPL 05 00V TRGL 4 To set the offset Press OFFS button to make the cursor stay under the offset value OFS Then use to change the offset value F 00021 00000kHz OFS...

Page 9: ...witch between frequency meter and counter 1 Frequency measurement mode ExtF 21 000kHz FUNC EXT TREQ Measure FREQ 2 Pulse counter mode CNTR 0 FUNC COUNGTER Measure COUNT Press OK button canreset the co...

Page 10: ...10 ms The step value is calculated by the instrument itself 9 Load Save function Press SYS button to enter Save Load function This function allow the user to save to or load from M0 M30 for frequency...

Page 11: ...w Press Output again to turn on the output F 00021 00000kHz AMPL 05 00V OFF Other Functions 1 Dual Channel TTL output 2 Buzzer It beeps each time press a button The beep will last a while if operation...

Page 12: ...5MHz Ramp Triangle 0 2MHz 0 5MHz 0 5MHz 0 5MHz Pulse 0 2MHz 0 5MHz 0 5MHz 0 5MHz TTL 0 2MHz 0 5MHz 0 5MHz 0 5MHz Others 0 2MHz 0 5MHz 0 5MHz 0 5MHz Resolution 10mHz 0 01Hz Accuracy 5 10 6 Stability 1...

Page 13: ...n 0 01V 0 001V Attenuated TTL output Electrical Level Amplitude 5Vpp Fan out 20 TTL Load Rise Fall Time 20ns CMOS output Low Electric Level 0 3V High Electric Level 1V 10V Rise Fall Time 20ns External...

Page 14: ...erial interface Communicati ng Speed 9600bps Protocol Command line mode protocol complete open Power Voltage Range DC12V Buzzer Can be turned on off by setting Operation Button controlled Environment...

Page 15: ...pecial purpose or use authorization Before the installation and use each parameter of the technical indexes in this manual should be referred to If this suggestion is not obeyed death or serious perso...

Page 16: ...duct is proven to be defective within the respective period FeelTech guarantees the free replacement or repair of products which are approved defective This product enjoy 1 year warranty since its del...

Reviews: