Operating the Generator
WARNING
In order to prevent electric shock caused by improper use, the generator should be
grounded. Connect a thick cable between the ground terminal of the generator and the
external ground source.
If the unit is used as a backup power source for a building, the connection of the
generator to its power system shall be carried out by a professional electrician and
must comply with the applicable laws and regulations. Otherwise, the power of the
generator may impact on the public circuit. If the power company employees or
others touch the wire in the meantime, it will lead to injury or even death; At the
same time, due to the impact of electricity, the generator may explode, burn or
cause the building electricity equipment to fire.
BE CAUTIOUS
When the generator is running continuously, do not exceed the rated power. In other
cases, pay attention to the total power of the connected equipment.
Do not exceed the rated current of the socket.
Do not use the generator for purposes that it cannot achieve. Please also observe the
following requirements:
Do not parallel generators with unauthorized units or use unauthorized parallel power
cables or boxes.
Do not extend the exhaust pipe
If a longer cable is required, use a flexible cable for with rubber sleeve (the cable should
comply with IEC standards).
The length of the extension cable is limited, the cable of 2mm
2
is 60 meters long; the
cable of 3mm
2
is 100 meters long.
The generator should be away from other electric wires or cables, such as: electricity
transmission network.
NOTICE
When using AC power, you can use DC power at the same time. Please pay attention to the
sum of the power of AC and DC. It cannot exceed the rated power of the generator.
17