4. CONNECTION
Coil the cord 2 or 3 times around the handle. Start
the engine.
Plug in the AC plug
5. SAFETY
a. Press the button to relocate the protector.
b. Reduce the AC load if the protector shuts down.
(1) = on (2) = out
6. RECURRING MAINTENANCE
1. Spark plug:
- Every 50 hours or once a month. Remove the spark plug.
Scrape the deposits of cinder. Check electrode discoloration
Check the electrode opening (standard 0.7 - 0.8 mm).
2. Air filter:
- Every 100 hours or once a month.
Remove the air filter. Clean it with water and soap
Pour motor oil.
Squeeze the motor oil.
3. Gas stopcock and filter:
- Every 150 hours or once every trimester
Open the stopcock
Stop the engine.