7
5. PREPARING BEFORE USING
a) Know your product
1- Air outlet connection
2- Hose
3- Trigger
4- Paint Container
5- Support bracket
6- Viscosity cup
7- Blowing nozzle
8- Carrying Belt
b) Technical data
1) Voltage: ...........................................230V~ 50Hz
2)
Power: ......................................................650W
3) Rotation speed : ................................31000/min
4) Technology :HVLP (High Volume Low Pressure)
5) Flow : ..........................................150 ml/min
6) Pressure : ....................................0.15 -0.35 bar
7) Nozzle diameter :......................... 1.8mm
8) Sound pressure level: ...........95dB(A), K=3dB(A)
9) Sound power level: ..............106dB(A), K=3dB(A)
10) Vibration: ..........................2,35m/s
2
, K=1.5m/s
2
Information:
- The declared vibration total value has been measured in accordance with a standard test method and
may be used for comparing one tool with another;
- The declared vibration total value may also be used in a preliminary assessment of exposure.
Warning:
- The vibration emission during actual use of the power tool can differ from the declared total value
depending on the ways in which the tool is used;
- need to identify safety measures to protect the operator that are based on an estimation of exposure in
the actual conditions of use (taking account of all parts of the operating cycle such as the times when
the tool is switched off and when it is running idle in addition to the trigger time).