OBID
®
classic pro
Installation
ID CPR.02-x
Page 32 of 36
FEIG ELECTRONIC GmbH
5. Technical data
casing
Plastic material ASA
colour
bottom part of casing:
top of casing:
similar to RAL 9002 (greyish white)
similar to RAL 7043 (traffic grey)
weight
approx. 120 g
protective system
IP 54
power supply
12 - 24 V AC/DC
power consumption
max. 2,6 W
temperature range
-25°C to 60°C
relative air humidity
95 % (non-condensing)
antenna
integrated
carrier frequency
13,65 MHz
supported Transponder types
•
according ISO14443-A
•
according ISO14443-B
•
according ISO15693
•
I-CODE1
signal transmitter
1 x bicolor-LED (red, green, orange)
1 x buzzer
relay
1 x normally open
capacity of contacts: 24 V AC/DC 1,5 A
digital inputs
2 x configurable
length of lead-in wire max. 3 m
interfaces
asynchrony (bi-directional) 4800 to 38400 Baud
•
RS232
(ID CPR.02-A)
length of lead-in wire max. 10 m
•
RS485
(ID CPR.02-B)
max. 32 units on each data bus
data / clock (unidirectional) TTL
length of lead-in wire max. 3 m
•
Magnetic Stripe
Emulation,
track 1 (7 Bit), track 2+3 (5 Bit)
•
Wiegand Emulation
DIP-switch
8-channel
EEPROM
10.000 writing cycles
Default values (factory alined):
asynchronous interface:
9600 Baud, 8 data- 1 stopbit, even parity
IN1
activates LED red and relay
IN2
aktivates LED green and buzzer
LED-operation control
orange