IDENTIFICATION
Installation
ID ISC.ANT1520/680-A/-B
FEIG ELECTRONIC GmbH
Page 22 of 82
ID ISC.ANT1520680-A-B User
Manual_M61112-1e-ID-E-
060317.doc
Transmitted
output power
Minimum Distance
< 0.5 W
1 m
0.5 W-1.0 W
2 m
1.1 W – 2.0 W
3 m
> 2 W
4 m
>= 4 W
8 m
Table 4: Minimum Distances
-
There should be no interference of the Reader from other electrical devices in the environment.
The Noise Level difference should be less than 20 mV.
-
The ID ISC.LRM2500 reader should be set to an RF power of 8 watts.
-
When using ISO 15693 transponders, the Readers should be set as described in
6.3.5 Reader
Configuration.
-
If multiple gates are operated at the same time at a distance of less than 8 m, the Readers
must by synchronized. See Application Note Synchronizing RFID Long Range Readers using
the digital in-/outputs (N10311-xe-ID-B.pdf).
Gate with antenna
Type A and Type B
Gate distance GD
≤
100 cm
Number of tags at a speed of
1 m/s
-
Read serial number
-
Read data
16
8
Table 5: Gate distance
Supplementary equipment (e.g. light barrier, lighting, etc.), mounted directly on the antenna or in
the immediate vicinity of the antenna can interference with the functioning of the system.
A minimum distance of 20 cm is required.
Electrical cable, directly at the antenna or in the immediate vicinity of the antenna, can be cause
interference. A minimum distance of 20 cm is required.
A minimum distance of 65cm between the two gate antennas is required.