IDENTIFICATION
Installation
ID ISC.ANT1520/680-A/-B
FEIG ELECTRONIC GmbH
Page 45 of 82
ID ISC.ANT1520680-A-B User
Manual_M61112-1e-ID-E-
060317.doc
6.5.2 Setting the LED´s
The alarm LED´s will be switched by a command of the reader over the RS485 Bus.
Due to that reason the terminal boards of all used antennas have to be connected 1:1 in parallel
together.
The Bus address for each LED will be defined by the antenna number it is installed in.
The antenna number depends on the output of the Multiplexer the antenna is connected to.
The Bus address will be set automatically after setup and configuration of the complete gate sys-
tem after a “System Reset” command in one of the Automatic Modes.
The successful detection of the connected LED´s could be checked
with the command “Get Reader Info”
The number of detected LED´s and it´s firmware version will be also displayed in the LCD Display
after a power up or the command “System Reset”.
LED in Antenna
No.
Connected to Multiplexer
Output No.
Bus Address No.
1
1
11
2
2
12
3
3
13
4
4
14
5
5
15
6
6
16
7
7
17
Table 8
The color of the LED could configured with the ISO-Start software. see
6.5.3 Reader Setting for
Alarm Indicators
The following colors could be set:
Red
Cyan
Magenta
Blue
Green
Yellow
White
Table 9